2012-07-21 16:56:21 +02:00
|
|
|
#
|
|
|
|
# For a description of the syntax of this configuration file,
|
|
|
|
# see misc/tools/kconfig-language.txt.
|
|
|
|
#
|
|
|
|
|
2012-07-21 17:33:53 +02:00
|
|
|
config MODBUS
|
|
|
|
bool "Modbus support via FreeModBus"
|
|
|
|
default n
|
|
|
|
|
2012-07-21 16:56:21 +02:00
|
|
|
config MB_ASCII_ENABLED
|
|
|
|
bool "Modbus ASCII support"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
|
|
|
|
config MB_RTU_ENABLED
|
|
|
|
bool "Modbus RTU support"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
|
|
|
|
config MB_TCP_ENABLED
|
|
|
|
bool "Modbus TCP support"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
|
|
|
|
config MB_ASCII_TIMEOUT_SEC
|
|
|
|
int "Character timeout"
|
|
|
|
depends on MB_ASCII_ENABLED
|
|
|
|
default 1
|
|
|
|
---help---
|
|
|
|
Character timeout value for Modbus ASCII
|
|
|
|
|
|
|
|
The character timeout value is not fixed for Modbus ASCII and is therefore
|
|
|
|
a configuration option. It should be set to the maximum expected delay
|
|
|
|
time of the network.
|
|
|
|
|
|
|
|
config MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS
|
|
|
|
int "Timeout to wait before sending"
|
|
|
|
depends on MB_ASCII_ENABLED
|
|
|
|
default 0
|
|
|
|
---help---
|
|
|
|
Timeout to wait in ASCII prior to enabling transmitter
|
|
|
|
|
|
|
|
If defined the function calls vMBPortSerialDelay with the argument
|
|
|
|
MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS to allow for a delay before
|
|
|
|
the serial transmitter is enabled. This is required because some
|
|
|
|
targets are so fast that there is no time between receiving and
|
2014-04-14 00:24:28 +02:00
|
|
|
transmitting the frame. If the master is to slow with enabling its
|
2012-07-21 16:56:21 +02:00
|
|
|
receiver then he will not receive the response correctly.
|
|
|
|
|
|
|
|
config MB_FUNC_HANDLERS_MAX
|
|
|
|
int "Maximum number of Modbus functions"
|
|
|
|
depends on MODBUS
|
|
|
|
default 16
|
|
|
|
---help---
|
|
|
|
Maximum number of Modbus functions codes the protocol stack should support.
|
|
|
|
|
|
|
|
The maximum number of supported Modbus functions must be greater than
|
|
|
|
the sum of all enabled functions in this file and custom function
|
|
|
|
handlers. If set to small adding more functions will fail.
|
|
|
|
|
|
|
|
config MB_FUNC_OTHER_REP_SLAVEID_BUF
|
|
|
|
int "Size of Slave ID report buffer"
|
|
|
|
depends on MB_FUNC_OTHER_REP_SLAVEID_ENABLED
|
|
|
|
default 32
|
|
|
|
---help---
|
|
|
|
Number of bytes which should be allocated for the Report Slave ID command.
|
|
|
|
|
|
|
|
This number limits the maximum size of the additional segment in the
|
|
|
|
report slave id function. See eMBSetSlaveID() for more information on
|
|
|
|
how to set this value. It is only used if MB_FUNC_OTHER_REP_SLAVEID_ENABLED
|
|
|
|
is set to 1.
|
|
|
|
|
|
|
|
config MB_FUNC_OTHER_REP_SLAVEID_ENABLED
|
|
|
|
bool "Report Slave ID function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Report Slave ID function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_READ_INPUT_ENABLED
|
|
|
|
bool "Read Input Registers function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Read Input Registers function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_READ_HOLDING_ENABLED
|
|
|
|
bool "Read Holding Registers function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Read Holding Registers function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_WRITE_HOLDING_ENABLED
|
|
|
|
bool "Write Single Register function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Write Single Register function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED
|
|
|
|
bool "Write Multiple registers function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Write Multiple registers function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_READ_COILS_ENABLED
|
|
|
|
bool "Read Coils function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Read Coils function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_WRITE_COIL_ENABLED
|
|
|
|
bool "Write Coils function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Write Coils function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED
|
|
|
|
bool "Write Multiple Coils function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Write Multiple Coils function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_READ_DISCRETE_INPUTS_ENABLED
|
|
|
|
bool "Read Discrete Inputs function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Read Discrete Inputs function should be enabled.
|
|
|
|
|
|
|
|
config MB_FUNC_READWRITE_HOLDING_ENABLED
|
|
|
|
bool "Read/Write Multiple Registers function"
|
|
|
|
depends on MODBUS
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If the Read/Write Multiple Registers function should be enabled.
|