2019-06-15 16:38:04 +02:00
|
|
|
The ABNT CODI is an old energy meter standard used in Brazil.
|
|
|
|
|
|
|
|
This code interprets the end user serial output existent in the energy meter.
|
|
|
|
That output externalizes its data blinking an LED as a serial protocol at the
|
|
|
|
baudrate of 110 BPS and uses 8 octects:
|
|
|
|
_____________________________________________________________________________
|
|
|
|
| | | |
|
2020-02-23 05:51:44 +01:00
|
|
|
| OCTET | bits | Description |
|
2019-06-15 16:38:04 +02:00
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 001 | 0-7 | Number of seconds to the end of current active demand (LSB) |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 002 | 0-3 | Number of seconds to the end of current active demand (MSB) |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 4 | Bill indicator. It is inverted at each demand replenishment |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 5 | Reactive Interval Indicator. Inverted at end react interval |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 6 | If 1 means the reactive-capacitive is used to calculate UFER|
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 7 | If 1 means the reactive-inductive is used to calculate UFER |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 003 | 0-3 | Current seasonal segment: |
|
|
|
|
| | | 0001 - tip |
|
|
|
|
| | | 0010 - out of tip |
|
|
|
|
| | | 1000 - reserved |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 4-5 | Type of charging indicator (flag): |
|
|
|
|
| | | 00 - Blue |
|
|
|
|
| | | 01 - Green |
|
|
|
|
| | | 10 - Irrigators |
|
|
|
|
| | | 11 - Other |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 6 | Not used |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 7 | If equal 1 means reactive rate is enabled |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 004 | 0-7 | Number of pulses for active energy of cur dem interv (LSB) |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 005 | 0-6 | Number of pulses for active energy of cur dem interv (MSB) |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 7 | Not used |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 006 | 0-7 | Number of pulses for reactive energy of cur dem interv (LSB)|
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 007 | 0-6 | Number of pulses for reactive energy of cur dem interv (MSB)|
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| | 7 | Not used |
|
|
|
|
|________|______|_____________________________________________________________|
|
|
|
|
| | | |
|
|
|
|
| 008 | 0-7 | Inverted bits of "xor" from previous octects |
|
|
|
|
|________|______|_____________________________________________________________|
|