remove industry/xxx/README.md and modbus/README.md. Migrated to Documentation/applications/industry

This commit is contained in:
raiden00pl 2023-10-24 14:07:34 +02:00 committed by Xiang Xiao
parent 24338bb477
commit 4dfd474ae9
2 changed files with 0 additions and 147 deletions

View File

@ -1,27 +0,0 @@
# Industry / `abnt_codi` ABNT CODI
The ABNT CODI is an old energy meter standard used in Brazil.
This code interprets the end user serial output existent in the energy meter.
That output externalizes its data blinking an LED as a serial protocol at the
baudrate of `110 BPS` and uses `8` octects:
| Octet | Bits | Description
|:-----:|------:|-------------
| `001` | `0-7` | Number of seconds to the end of current active demand (`LSB`)
| `002` | `0-3` | Number of seconds to the end of current active demand (`MSB`)
| | `4` | Bill indicator. It is inverted at each demand replenishment
| | `5` | Reactive Interval Indicator. Inverted at end react interval
| | `6` | If `1` means the reactive-capacitive is used to calculate `UFER`
| | `7` | If `1` means the reactive-inductive is used to calculate `UFER`
| `003` | `0-3` | Current seasonal segment: <br> `0001` tip <br> `0010` out of tip <br> `1000` reserved
| | `4-5` | Type of charging indicator (flag): <br> `00` Blue <br> `01` Green <br> `10` Irrigators <br> `11` Other
| | `6` | Not used
| | `7` | If equal `1` means reactive rate is enabled
| `004` | `0-7` | Number of pulses for active energy of cur dem interv (`LSB`)
| `005` | `0-6` | Number of pulses for active energy of cur dem interv (`MSB`)
| | `7` | Not used
| `006` | `0-7` | Number of pulses for reactive energy of cur dem interv (`LSB`)
| `007` | `0-6` | Number of pulses for reactive energy of cur dem interv (`MSB`)
| | `7` | Not used
| `008` | `0-7` | Inverted bits of _xor_ from previous octects

View File

@ -1,120 +0,0 @@
# Modbus
This directory contains a port of last open source version of FreeModBus (BSD
license). The code in this directory is a subset of FreeModBus version 1.5.0
(June 6, 2010) that can be downloaded in its entirety from
http://developer.berlios.de/project/showfiles.php?group_id=6120.
Includes extensions to support RTU master mode by Armink(383016632@qq.com):
https://github.com/armink/FreeModbus_Slave-Master-RTT-STM32. Ported to NuttX by
Darcy Gong.
## Directory Structure / Relation to freemodbus-v1.5.0
The original FreeModBus download consists of several directories. This subset
takes only the contents of one directory, `modbus/`, that implements the core
modbus logic and integrates that directory into the NuttX build system. The
mapping between `freemodbus-v1.5.0` and the nuttx directories is shown below:
```
--------------------------- ----------------------------------------------
freemodbus-v1.5.0 NuttX
--------------------------- ----------------------------------------------
All top level .txt files Not included
demo/ Not included. This directory contains demo
and porting code for a variety of platforms.
The NuttX demo was ported from the LINUX
demo in this directory and can be found at
apps/examples/modbus.
doc/ Not included. This directory contains Doxygen
support files.
modbus/ Included in its entirety in various locations:
ascii apps/modbus/ascii
functions apps/modbus/functions
include apps/include/modbus
mb.c apps/modbus/mb.c
rtu apps/modbus/rtu
tcp apps/modbus/tcp
tools/ Not included. This directory contains Doxygen
tools.
--------------------------- ----------------------------------------------
```
So this directory is equivalent to the `freemodbus-v1.5.0/modbus` directory
except that (1) it may include modifications for the integration with NuttX and
(2) the modbus/include directory was moved to `apps/modbus`.
The original, unmodified `freemodbus-v1.5.0` was checked in as SVN revision
`4960`.
The other directory here, `nuttx/`, implements the NuttX modbus interface. It
derives from the `freemodbus-v1.5.0/demo/LINUX/port` directory.
## Configuration Options
In the original `freemodbus-v1.5.0` release, the FreeModBus configuration was
controlled by the header file `mbconfig.h`. This header file was eliminated
(post revision `4960`) and the FreeModBus configuration was integrated into the
NuttX configuration system.
The NuttX-named configuration options that are available include:
- `CONFIG_MODBUS` General ModBus support.
- `CONFIG_MB_ASCII_ENABLED` Modbus ASCII support.
- `CONFIG_MB_ASCII_MASTER` Modbus ASCII master support.
- `CONFIG_MB_RTU_ENABLED` Modbus RTU support.
- `CONFIG_MB_RTU_MASTER` Modbus RTU master support.
- `CONFIG_MB_TCP_ENABLED` Modbus TCP support.
- `CONFIG_MB_ASCII_TIMEOUT_SEC` Character timeout value for Modbus ASCII. The
character timeout value is not fixed for Modbus ASCII and is therefore a
configuration option. It should be set to the maximum expected delay time of
the network. Default: `1`.
- `CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS` Timeout to wait in ASCII prior
to enabling transmitter. If defined the function calls `vMBPortSerialDelay`
with the argument `CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS` to allow for a
delay before the serial transmitter is enabled. This is required because some
targets are so fast that there is no time between receiving and transmitting
the frame. If the master is too slow with enabling its receiver then it will
not receive the response correctly.
- `CONFIG_MB_FUNC_HANDLERS_MAX` Maximum number of Modbus functions codes the
protocol stack should support. The maximum number of supported Modbus
functions must be greater than the sum of all enabled functions in this file
and custom function handlers. If set too small, adding more functions will
fail.
- `CONFIG_MB_FUNC_OTHER_REP_SLAVEID_BUF` Number of bytes which should be
allocated for the Report Slave ID command. This number limits the maximum size
of the additional segment in the report slave id function. See
`eMBSetSlaveID()` for more information on how to set this value. It is only
used if `CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED` is set to `1`.
- `CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED` If the Report Slave ID function
should be enabled.
- `CONFIG_MB_FUNC_READ_INPUT_ENABLED` If the Read Input Registers function
should be enabled.
- `CONFIG_MB_FUNC_READ_HOLDING_ENABLED` If the Read Holding Registers function
should be enabled.
- `CONFIG_MB_FUNC_WRITE_HOLDING_ENABLED` If the Write Single Register function
should be enabled.
- `CONFIG_MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED` If the Write Multiple
registers function should be enabled.
- `CONFIG_MB_FUNC_READ_COILS_ENABLED` If the Read Coils function should be
enabled.
- `CONFIG_MB_FUNC_WRITE_COIL_ENABLED` If the Write Coils function should be
enabled.
- `CONFIG_MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED` If the Write Multiple Coils
function should be enabled.
- `CONFIG_MB_FUNC_READ_DISCRETE_INPUTS_ENABLED` If the Read Discrete Inputs
function should be enabled.
- `CONFIG_MB_FUNC_READWRITE_HOLDING_ENABLED` If the Read/Write Multiple
Registers function should be enabled.
See also other serial settings, in particular:
- `CONFIG_SERIAL_TERMIOS` Serial driver supports `termios.h` interfaces
If this is not defined, then the terminal settings (baud, parity, etc.)
are not configurable at runtime.
## Note
The developer of FreeModBus, Christian Walter, is still developing Modbus
libraries, although they are now commercial. See
http://www.embedded-solutions.at/ for further information.