1511403fdf
This reverts commit
|
||
---|---|---|
.. | ||
ascii | ||
functions | ||
nuttx | ||
rtu | ||
tcp | ||
.gitignore | ||
Kconfig | ||
Make.defs | ||
Makefile | ||
mb_m.c | ||
mb.c | ||
README.txt |
apps/modbus README ================== This directory contains a port of last open source version of FreeModBus (BSD license). The code in this directory is a subset of FreeModBus version 1.5.0 (June 6, 2010) that can be downloaded in its entirety from http://developer.berlios.de/project/showfiles.php?group_id=6120. Includes extensions to support RTU master mode by Armink(383016632@qq.com): https://github.com/armink/FreeModbus_Slave-Master-RTT-STM32. Ported to NuttX by Darcy Gong. Directory Structure/Relation to freemodbus-v1.5.0 ------------------------------------------------- The original FreeModBus download consists of several directories. This subset takes only the contents of one directory, modbus/, that implements the core modbus logic and integrates that directory into the NuttX build system. The mapping between freemodbus-v1.5.0 and the nuttx directories is shown below: --------------------------- ---------------------------------------------- freemodbus-v1.5.0 NuttX --------------------------- ---------------------------------------------- All top level .txt files Not included demo/ Not included. This directory contains demo and porting code for a variety of platforms. The NuttX demo was ported from the LINUX demo in this directory and can be found at apps/examples/modbus. doc/ Not included. This directory contains Doxygen support files. modbus/ Included in its entirety in various locations: ascii apps/modbus/ascii functions apps/modbus/functions include apps/include/modbus mb.c apps/modbus/mb.c rtu apps/modbus/rtu tcp apps/modbus/tcp tools/ Not included. This directory contains Doxygen tools. --------------------------- ---------------------------------------------- So this directory is equivalent to the freemodbus-v1.5.0/modbus directory except that (1) it may include modifications for the integration with NuttX and (2) the modbus/include directory was moved to apps/modbus. The original, unmodified freemodbus-v1.5.0 was checked in as SVN revision 4960. The other directory here, nuttx/, implements the NuttX modbus interface. It derives from the freemodbus-v1.5.0/demo/LINUX/port directory. Configuration Options ===================== In the original freemodbus-v1.5.0 release, the FreeModBus configuration was controlled by the header file mbconfig.h. This header file was eliminated (post revision 4960) and the FreeModBus configuration was integrated into the NuttX configuration system. The NuttX-named configuration options that are available include: CONFIG_MODBUS - General ModBus support CONFIG_MB_ASCII_ENABLED - Modbus ASCII support CONFIG_MB_ASCII_MASTER - Modbus ASCII master support CONFIG_MB_RTU_ENABLED - Modbus RTU support CONFIG_MB_RTU_MASTER - Modbus RTU master support CONFIG_MB_TCP_ENABLED - Modbus TCP support CONFIG_MB_ASCII_TIMEOUT_SEC - Character timeout value for Modbus ASCII. The character timeout value is not fixed for Modbus ASCII and is therefore a configuration option. It should be set to the maximum expected delay time of the network. Default 1 CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS - Timeout to wait in ASCII prior to enabling transmitter. If defined the function calls vMBPortSerialDelay with the argument CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS to allow for a delay before the serial transmitter is enabled. This is required because some targets are so fast that there is no time between receiving and transmitting the frame. If the master is too slow with enabling its receiver then it will not receive the response correctly. CONFIG_MB_FUNC_HANDLERS_MAX - Maximum number of Modbus functions codes the protocol stack should support. The maximum number of supported Modbus functions must be greater than the sum of all enabled functions in this file and custom function handlers. If set too small, adding more functions will fail. CONFIG_MB_FUNC_OTHER_REP_SLAVEID_BUF - Number of bytes which should be allocated for the Report Slave ID command. This number limits the maximum size of the additional segment in the report slave id function. See eMBSetSlaveID() for more information on how to set this value. It is only used if CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED is set to 1. CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED - If the Report Slave ID function should be enabled. CONFIG_MB_FUNC_READ_INPUT_ENABLED - If the Read Input Registers function should be enabled. CONFIG_MB_FUNC_READ_HOLDING_ENABLED - If the Read Holding Registers function should be enabled. CONFIG_MB_FUNC_WRITE_HOLDING_ENABLED - If the Write Single Register function should be enabled. CONFIG_MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED - If the Write Multiple registers function should be enabled. CONFIG_MB_FUNC_READ_COILS_ENABLED - If the Read Coils function should be enabled. CONFIG_MB_FUNC_WRITE_COIL_ENABLED - If the Write Coils function should be enabled. CONFIG_MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED - If the Write Multiple Coils function should be enabled. CONFIG_MB_FUNC_READ_DISCRETE_INPUTS_ENABLED - If the Read Discrete Inputs function should be enabled. CONFIG_MB_FUNC_READWRITE_HOLDING_ENABLED - If the Read/Write Multiple Registers function should be enabled. See also other serial settings, in particular: CONFIG_SERIAL_TERMIOS - Serial driver supports termios.h interfaces (tcsetattr, tcflush, etc.). If this is not defined, then the terminal settings (baud, parity, etc.) are not configurable at runtime; serial streams will not be flushed when closed. Note ==== The developer of FreeModBus, Christian Walter, is still developing Modbus libraries, although they are now commercial. See http://www.embedded-solutions.at/ for further information.