Industry / abnt_codi
ABNT CODI
The ABNT CODI is an old energy meter standard used in Brazil.
This code interprets the end user serial output existent in the energy meter.
That output externalizes its data blinking an LED as a serial protocol at the
baudrate of 110 BPS
and uses 8
octects:
Octet | Bits | Description |
---|---|---|
001 |
0-7 |
Number of seconds to the end of current active demand (LSB ) |
002 |
0-3 |
Number of seconds to the end of current active demand (MSB ) |
4 |
Bill indicator. It is inverted at each demand replenishment | |
5 |
Reactive Interval Indicator. Inverted at end react interval | |
6 |
If 1 means the reactive-capacitive is used to calculate UFER |
|
7 |
If 1 means the reactive-inductive is used to calculate UFER |
|
003 |
0-3 |
Current seasonal segment: 0001 – tip 0010 – out of tip 1000 – reserved |
4-5 |
Type of charging indicator (flag): 00 – Blue 01 – Green 10 – Irrigators 11 – Other |
|
6 |
Not used | |
7 |
If equal 1 means reactive rate is enabled |
|
004 |
0-7 |
Number of pulses for active energy of cur dem interv (LSB ) |
005 |
0-6 |
Number of pulses for active energy of cur dem interv (MSB ) |
7 |
Not used | |
006 |
0-7 |
Number of pulses for reactive energy of cur dem interv (LSB ) |
007 |
0-6 |
Number of pulses for reactive energy of cur dem interv (MSB ) |
7 |
Not used | |
008 |
0-7 |
Inverted bits of xor from previous octects |