# Modbus
|
||
|
||
This directory contains a port of last open source version of FreeModBus (BSD
|
||
license). The code in this directory is a subset of FreeModBus version 1.5.0
|
||
(June 6, 2010) that can be downloaded in its entirety from
|
||
http://developer.berlios.de/project/showfiles.php?group_id=6120.
|
||
|
||
Includes extensions to support RTU master mode by Armink(383016632@qq.com):
|
||
https://github.com/armink/FreeModbus_Slave-Master-RTT-STM32. Ported to NuttX by
|
||
Darcy Gong.
|
||
|
||
## Directory Structure / Relation to freemodbus-v1.5.0
|
||
|
||
The original FreeModBus download consists of several directories. This subset
|
||
takes only the contents of one directory, `modbus/`, that implements the core
|
||
modbus logic and integrates that directory into the NuttX build system. The
|
||
mapping between `freemodbus-v1.5.0` and the nuttx directories is shown below:
|
||
|
||
```
|
||
--------------------------- ----------------------------------------------
|
||
freemodbus-v1.5.0 NuttX
|
||
--------------------------- ----------------------------------------------
|
||
All top level .txt files Not included
|
||
demo/ Not included. This directory contains demo
|
||
and porting code for a variety of platforms.
|
||
The NuttX demo was ported from the LINUX
|
||
demo in this directory and can be found at
|
||
apps/examples/modbus.
|
||
doc/ Not included. This directory contains Doxygen
|
||
support files.
|
||
modbus/ Included in its entirety in various locations:
|
||
ascii apps/modbus/ascii
|
||
functions apps/modbus/functions
|
||
include apps/include/modbus
|
||
mb.c apps/modbus/mb.c
|
||
rtu apps/modbus/rtu
|
||
tcp apps/modbus/tcp
|
||
tools/ Not included. This directory contains Doxygen
|
||
tools.
|
||
--------------------------- ----------------------------------------------
|
||
```
|
||
|
||
So this directory is equivalent to the `freemodbus-v1.5.0/modbus` directory
|
||
except that (1) it may include modifications for the integration with NuttX and
|
||
(2) the modbus/include directory was moved to `apps/modbus`.
|
||
|
||
The original, unmodified `freemodbus-v1.5.0` was checked in as SVN revision
|
||
`4960`.
|
||
|
||
The other directory here, `nuttx/`, implements the NuttX modbus interface. It
|
||
derives from the `freemodbus-v1.5.0/demo/LINUX/port` directory.
|
||
|
||
## Configuration Options
|
||
|
||
In the original `freemodbus-v1.5.0` release, the FreeModBus configuration was
|
||
controlled by the header file `mbconfig.h`. This header file was eliminated
|
||
(post revision `4960`) and the FreeModBus configuration was integrated into the
|
||
NuttX configuration system.
|
||
|
||
The NuttX-named configuration options that are available include:
|
||
|
||
- `CONFIG_MODBUS` – General ModBus support.
|
||
- `CONFIG_MB_ASCII_ENABLED` – Modbus ASCII support.
|
||
- `CONFIG_MB_ASCII_MASTER` – Modbus ASCII master support.
|
||
- `CONFIG_MB_RTU_ENABLED` – Modbus RTU support.
|
||
- `CONFIG_MB_RTU_MASTER` – Modbus RTU master support.
|
||
- `CONFIG_MB_TCP_ENABLED` – Modbus TCP support.
|
||
- `CONFIG_MB_ASCII_TIMEOUT_SEC` – Character timeout value for Modbus ASCII. The
|
||
character timeout value is not fixed for Modbus ASCII and is therefore a
|
||
configuration option. It should be set to the maximum expected delay time of
|
||
the network. Default: `1`.
|
||
- `CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS` – Timeout to wait in ASCII prior
|
||
to enabling transmitter. If defined the function calls `vMBPortSerialDelay`
|
||
with the argument `CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS` to allow for a
|
||
delay before the serial transmitter is enabled. This is required because some
|
||
targets are so fast that there is no time between receiving and transmitting
|
||
the frame. If the master is too slow with enabling its receiver then it will
|
||
not receive the response correctly.
|
||
- `CONFIG_MB_FUNC_HANDLERS_MAX` – Maximum number of Modbus functions codes the
|
||
protocol stack should support. The maximum number of supported Modbus
|
||
functions must be greater than the sum of all enabled functions in this file
|
||
and custom function handlers. If set too small, adding more functions will
|
||
fail.
|
||
- `CONFIG_MB_FUNC_OTHER_REP_SLAVEID_BUF` – Number of bytes which should be
|
||
allocated for the Report Slave ID command. This number limits the maximum size
|
||
of the additional segment in the report slave id function. See
|
||
`eMBSetSlaveID()` for more information on how to set this value. It is only
|
||
used if `CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED` is set to `1`.
|
||
- `CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED` – If the Report Slave ID function
|
||
should be enabled.
|
||
- `CONFIG_MB_FUNC_READ_INPUT_ENABLED` – If the Read Input Registers function
|
||
should be enabled.
|
||
- `CONFIG_MB_FUNC_READ_HOLDING_ENABLED` – If the Read Holding Registers function
|
||
should be enabled.
|
||
- `CONFIG_MB_FUNC_WRITE_HOLDING_ENABLED` – If the Write Single Register function
|
||
should be enabled.
|
||
- `CONFIG_MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED` – If the Write Multiple
|
||
registers function should be enabled.
|
||
- `CONFIG_MB_FUNC_READ_COILS_ENABLED` – If the Read Coils function should be
|
||
enabled.
|
||
- `CONFIG_MB_FUNC_WRITE_COIL_ENABLED` – If the Write Coils function should be
|
||
enabled.
|
||
- `CONFIG_MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED` – If the Write Multiple Coils
|
||
function should be enabled.
|
||
- `CONFIG_MB_FUNC_READ_DISCRETE_INPUTS_ENABLED` – If the Read Discrete Inputs
|
||
function should be enabled.
|
||
- `CONFIG_MB_FUNC_READWRITE_HOLDING_ENABLED` – If the Read/Write Multiple
|
||
Registers function should be enabled.
|
||
|
||
See also other serial settings, in particular:
|
||
|
||
- `CONFIG_SERIAL_TERMIOS` – Serial driver supports `termios.h` interfaces
|
||
If this is not defined, then the terminal settings (baud, parity, etc.)
|
||
are not configurable at runtime.
|
||
|
||
## Note
|
||
|
||
The developer of FreeModBus, Christian Walter, is still developing Modbus
|
||
libraries, although they are now commercial. See
|
||
http://www.embedded-solutions.at/ for further information.
|