Segger RTT drivers
==================
.. note:: Segger drivers works only with J-Link debug probes.
Sometimes it's possible to replace vendor-specific debug interface
with J-Link OB firmware. For details look at
`Segger website <https://www.segger.com/downloads/jlink>`_
Supported Segger drivers:
* Serial over RTT - ``CONFIG_SERIAL_RTTx``,
* Console over RTT - ``CONFIG_SERIAL_RTT_CONSOLE_CHANNEL``
* Segger SystemView - ``CONFIG_SEGGER_SYSVIEW``
* Note RTT - ``CONFIG_NOTE_RTT``
Segger SystemView
=================
Steps to enable SystemView support:
#. Make sure your architecture supports a high-performance counter.
In most cases it will be:
:menuselection:`CONFIG_ARCH_PERF_EVENTS=y`
In that case, the the architecture logic must initialize the perf counter
with ``up_perf_init()``.
#. Enable instrumentation support:
:menuselection:`CONFIG_SCHED_INSTRUMENTATION=y`
#. Configure instrumentation support. Available options for SystemView are:
:menuselection:`CONFIG_SCHED_INSTRUMENTATION_SWITCH=y`
:menuselection:`CONFIG_SCHED_INSTRUMENTATION_SYSCALL=y`
:menuselection:`CONFIG_SCHED_INSTRUMENTATION_IRQHANDLER=y`
#. Make sure that ``CONFIG_TASK_NAME_SIZE > 0``, otherwise task/thread
names will not be displayed correctly
#. Enable Note Driver support and disable Note RAM driver:
:menuselection:`CONFIG_DRIVERS_NOTE=y`
:menuselection:`CONFIG_DRIVERS_NOTERAM=n`
#. Enable Note RTT and Segger SystemView support:
:menuselection:`CONFIG_NOTE_RTT=y`
:menuselection:`CONFIG_SEGGER_SYSVIEW=y`
#. Configure RTT channel and RTT buffer size for SystemView:
:menuselection:`CONFIG_SEGGER_SYSVIEW_RTT_CHANNEL=0`
:menuselection:`CONFIG_SEGGER_SYSVIEW_RTT_BUFFER_SIZE=1024`
In case SystemView returns buffer overflow errors, you should increase
``CONFIG_NOTE_RTT_BUFFER_SIZE_UP``.