2022-08-01 11:31:49 +02:00
|
|
|
#
|
|
|
|
# For a description of the syntax of this configuration file,
|
|
|
|
# see the file kconfig-language.txt in the NuttX tools repository.
|
|
|
|
#
|
|
|
|
|
|
|
|
menu "Power Supply Support"
|
|
|
|
|
|
|
|
config DRIVERS_POWERLED
|
|
|
|
bool "High Power LED driver"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
Enables building of an powerled upper half driver.
|
|
|
|
|
|
|
|
menuconfig DRIVERS_SMPS
|
|
|
|
bool "Switched-Mode Power Supply (SMPS)"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
Enables building of an SMPS upper half driver.
|
|
|
|
|
|
|
|
if DRIVERS_SMPS
|
|
|
|
|
|
|
|
config SMPS_HAVE_OUTPUT_VOLTAGE
|
|
|
|
bool "Have Output Voltage"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config SMPS_HAVE_OUTPUT_CURRENT
|
|
|
|
bool "Have Output Current"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config SMPS_HAVE_OUTPUT_POWER
|
|
|
|
bool "Have Output Power"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config SMPS_HAVE_INPUT_VOLTAGE
|
|
|
|
bool "Have Input Voltage"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config SMPS_HAVE_INPUT_CURRENT
|
|
|
|
bool "Have Input Current"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config SMPS_HAVE_INPUT_POWER
|
|
|
|
bool "Have Input Power"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config SMPS_HAVE_EFFICIENCY
|
|
|
|
bool "Have Power Efficiency"
|
|
|
|
default n
|
|
|
|
|
|
|
|
endif
|
|
|
|
|
|
|
|
config REGULATOR
|
|
|
|
bool "Regulator core driver support"
|
|
|
|
default n
|
|
|
|
---help---
|
2023-01-11 17:57:16 +01:00
|
|
|
The regulator core driver implements the upper layer framework that the lower
|
2022-08-01 11:31:49 +02:00
|
|
|
layer driver can register with, and the common regulator APIs that are easy
|
|
|
|
for other drivers to call for the control of their power supply.
|
|
|
|
|
|
|
|
if REGULATOR
|
|
|
|
|
|
|
|
config REGULATOR_GPIO
|
|
|
|
bool "Regulator gpio driver support"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
The regulator gpio driver implements the lower regulator ops that use gpio to
|
|
|
|
control to regulator.
|
|
|
|
|
|
|
|
config REGULATOR_RPMSG
|
2023-10-27 12:56:33 +02:00
|
|
|
bool "Regulator RPMSG driver support"
|
2022-08-01 11:31:49 +02:00
|
|
|
depends on RPTUN
|
|
|
|
default n
|
|
|
|
---help---
|
2023-10-27 12:56:33 +02:00
|
|
|
The RPMSG regulator driver implements the common regulator APIs, inside which
|
2022-08-01 11:31:49 +02:00
|
|
|
the regulator operations are sent from the client to the remote device via
|
2023-10-27 12:56:33 +02:00
|
|
|
the RPMSG channel. The remote device(namely server) is responsible for
|
2022-08-01 11:31:49 +02:00
|
|
|
the parse and the completion.
|
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
menuconfig REGULATOR_ACT8945A
|
|
|
|
bool "Qorvo ACT8945A regulator support - MAKE CHANGES WITH CARE"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
-----------------------------------------------------------------------
|
|
|
|
TAKE GREAT CARE - BOARD DAMAGE MAY RESULT FROM INNAPPROPIATE CHANGES
|
|
|
|
-----------------------------------------------------------------------
|
|
|
|
|
|
|
|
The ACT8945A regulator driver implements the lower regulator ops thats
|
|
|
|
use I2C to control the regulator functions.
|
|
|
|
|
|
|
|
if REGULATOR_ACT8945A
|
|
|
|
|
|
|
|
menu "ACT8945A Regulator System Functions"
|
|
|
|
|
|
|
|
choice
|
|
|
|
prompt "ACT8945A SYSLEV threshold"
|
|
|
|
default ACT8945A_SYSLEV_3000
|
2023-05-18 11:52:54 +02:00
|
|
|
---help---
|
2023-01-11 17:57:16 +01:00
|
|
|
The SYSLEV voltage below which the configured SYSLEV mode will be triggered.
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_2300
|
|
|
|
bool "2.3V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_2400
|
|
|
|
bool "2.4V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_2500
|
|
|
|
bool "2.5"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_2600
|
|
|
|
bool "2.6V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_2700
|
|
|
|
bool "2.7V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_2800
|
|
|
|
bool "2.8V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_2900
|
|
|
|
bool "2.9V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3000
|
|
|
|
bool "3.0V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3100
|
|
|
|
bool "3.1V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3200
|
|
|
|
bool "3.2V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3300
|
|
|
|
bool "3.3V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3400
|
|
|
|
bool "3.4V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3500
|
|
|
|
bool "3.5V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3600
|
|
|
|
bool "3.6V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3700
|
|
|
|
bool "3.7V"
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_3800
|
|
|
|
bool "3.8V"
|
|
|
|
|
|
|
|
endchoice # ACT8945A SYSLEV threshold
|
|
|
|
|
2023-02-25 19:14:11 +01:00
|
|
|
choice
|
2023-01-11 17:57:16 +01:00
|
|
|
prompt "ACT8945A SYSLEV mode"
|
|
|
|
default ACT8945A_SYSLEV_MODE_INTERRUPT
|
|
|
|
---help---
|
|
|
|
Determines the response to the SYSLEV voltage detector
|
|
|
|
- Generate an interrupt when Vsys < SYSLEV threshold, or
|
|
|
|
- Automatic shutdown when Vsys < SYSLEV threshold
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_MODE_INTERRUPT
|
|
|
|
bool "Interrupt"
|
|
|
|
---help---
|
|
|
|
Generates an interrupt when Vsys < SYSLEV threshold.
|
|
|
|
Selecting this will unmask the SYSLEV interrupt as well.
|
|
|
|
|
|
|
|
config ACT8945A_SYSLEV_MODE_SHUTDOWN
|
|
|
|
bool "Shutdown"
|
|
|
|
---help---
|
|
|
|
Automatic shutdown when Vsys < SYSLEV threshold
|
|
|
|
|
|
|
|
endchoice # ACT8945A_SYSLEV_MODE
|
|
|
|
|
|
|
|
choice
|
|
|
|
prompt "ACT8945A Reset Timer Setting"
|
|
|
|
default ACT8945A_TRST_64
|
|
|
|
---help---
|
|
|
|
Defines the reset timeout threshold.
|
|
|
|
|
|
|
|
config ACT8945A_TRST_64
|
|
|
|
bool "64ms"
|
|
|
|
|
|
|
|
config ACT8945A_TRST_260
|
|
|
|
bool "260ms"
|
|
|
|
|
|
|
|
endchoice # ACT8945A Reset Timer Setting
|
|
|
|
|
|
|
|
endmenu # ACT8945A System Functions
|
|
|
|
|
|
|
|
menu "ACT8945A DCDC1 Configuration"
|
|
|
|
|
|
|
|
config ACT8945A_DCDC1_NAME
|
|
|
|
string "DCDC1 name"
|
|
|
|
default "ACT8945A_DCDC1"
|
|
|
|
---help---
|
|
|
|
This is the name used for the ACT8945A DCDC converter output 1.
|
|
|
|
It is used as the consumer name when you get or put a regulator.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC1_BOOT_ON
|
|
|
|
bool "Enable DCDC1"
|
|
|
|
default y
|
|
|
|
|
|
|
|
config ACT8945A_DCDC1_APPLY_UV
|
|
|
|
bool "Apply DCDC1 new voltage at initialisation"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
If set, the driver will attempt to set the voltage nearest to MIN_UV,
|
|
|
|
that is also lower than MAX_UV, during initialisation.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
If not set, MIN_UV and MAX_UV values will be ignored
|
|
|
|
during initialisation.
|
|
|
|
|
|
|
|
If the regulator is enabled here, and APPLY_UV=y, the board
|
|
|
|
voltage will actually change during initialisation.
|
|
|
|
|
|
|
|
If the regulator is not enabled here, and APPLY_UV=y, the
|
|
|
|
regulator voltage will be applied to the device in readiness for
|
|
|
|
the regulator being enabled later.
|
|
|
|
|
|
|
|
DO NOT CHANGE THIS UNLESS YOU KNOW WHAT YOU ARE DOING! It is usually
|
|
|
|
a critical processor voltage rail.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC1_MIN_UV
|
|
|
|
int "The minimum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, the voltage nearest to this, and less than
|
|
|
|
MAX_UV will be applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC1_MAX_UV
|
|
|
|
int "The maximum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, this is the maximum voltage that will be
|
|
|
|
applied during initialisation.
|
|
|
|
|
|
|
|
endmenu # ACT8945A DCDC1 Configuration
|
|
|
|
|
|
|
|
menu "ACT8945A DCDC2 Configuration"
|
|
|
|
|
|
|
|
config ACT8945A_DCDC2_NAME
|
|
|
|
string "DCDC2 name"
|
|
|
|
default "ACT8945A_DCDC2"
|
|
|
|
---help---
|
|
|
|
This is the name used for the ACT8945A DCDC converter output 2.
|
|
|
|
It is used as the consumer name when you get or put a regulator.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
config ACT8945A_DCDC2_BOOT_ON
|
|
|
|
bool "Enable DCDC2"
|
|
|
|
default y
|
|
|
|
|
|
|
|
config ACT8945A_DCDC2_APPLY_UV
|
|
|
|
bool "Apply DCDC2 new voltage at initialisation"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
If set, the driver will attempt to set the voltage nearest to MIN_UV,
|
|
|
|
that is also lower than MAX_UV, during initialisation.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
If not set, MIN_UV and MAX_UV values will be ignored
|
|
|
|
during initialisation.
|
|
|
|
|
|
|
|
If the regulator is enabled here, and APPLY_UV=y, the board
|
|
|
|
voltage will actually change during initialisation.
|
|
|
|
|
|
|
|
If the regulator is not enabled here, and APPLY_UV=Y, the
|
|
|
|
regulator voltage will be applied to the device in readiness for
|
|
|
|
the regulator being enabled later.
|
|
|
|
|
|
|
|
DO NOT CHANGE THIS UNLESS YOU KNOW WHAT YOU ARE DOING! It is usually
|
|
|
|
a critical processor voltage rail.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC2_MIN_UV
|
|
|
|
int "The minimum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, the voltage nearest to this, and less than
|
|
|
|
MAX_UV will be applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC2_MAX_UV
|
|
|
|
int "The maximum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, this is the maximum voltage that will be
|
|
|
|
applied during initialisation.
|
|
|
|
|
|
|
|
endmenu # ACT8945A DCDC2 Configuration
|
|
|
|
|
|
|
|
menu "ACT8945A DCDC3 Configuration"
|
|
|
|
|
|
|
|
config ACT8945A_DCDC3_NAME
|
|
|
|
string "DCDC3 name"
|
|
|
|
default "ACT8945A_DCDC3"
|
|
|
|
---help---
|
|
|
|
This is the name used for the ACT8945A DCDC converter output 3.
|
|
|
|
It is used as the consumer name when you get or put a regulator.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC3_BOOT_ON
|
|
|
|
bool "Enable DCDC3"
|
|
|
|
default y
|
|
|
|
|
|
|
|
config ACT8945A_DCDC3_APPLY_UV
|
|
|
|
bool "Apply DCDC3 new voltage at initialisation"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
If set to 1, the driver will attempt to set the voltage nearest to MIN_UV,
|
|
|
|
that is also lower than MAX_UV, during initialisation.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
If set to 0, MIN_UV and MAX_UV values will be ignored
|
|
|
|
during initialisation.
|
|
|
|
|
|
|
|
If the regulator is enabled here, and APPLY_UV=y, the board
|
|
|
|
voltage will actually change during initialisation.
|
|
|
|
|
|
|
|
If the regulator is not enabled here, and APPLY_UV=y, the
|
|
|
|
regulator voltage will be applied to the device in readiness for
|
|
|
|
the regulator being enabled later.
|
|
|
|
|
|
|
|
DO NOT CHANGE THIS UNLESS YOU KNOW WHAT YOU ARE DOING! It is usually
|
|
|
|
a critical processor voltage rail.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC3_MIN_UV
|
|
|
|
int "The minimum acceptable output voltage (600-3900mV)"
|
|
|
|
default 3300
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, the voltage nearest to this, and less than
|
|
|
|
MAX_UV will be applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_DCDC3_MAX_UV
|
|
|
|
int "The maximum acceptable output voltage (600-3900mV)"
|
|
|
|
default 3300
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, this is the maximum voltage that will be
|
|
|
|
applied during initialisation.
|
|
|
|
|
|
|
|
endmenu # ACT8945A DCDC 3 Configuration
|
|
|
|
|
|
|
|
menu "ACT8945A LDO Output 1 Configuration"
|
|
|
|
|
|
|
|
config ACT8945A_LDO1_NAME
|
|
|
|
string "LDO1 name"
|
|
|
|
default "ACT8945A_LDO1"
|
|
|
|
---help---
|
|
|
|
This is the name used for the ACT8945A LDO converter output 1.
|
|
|
|
It is used as the consumer name when you get or put a regulator.
|
|
|
|
|
|
|
|
config ACT8945A_LDO1_BOOT_ON
|
|
|
|
bool "Enable LDO1"
|
|
|
|
default y
|
|
|
|
|
|
|
|
config ACT8945A_LDO1_APPLY_UV
|
|
|
|
bool "Apply LDO1 new voltage at initialisation"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
If set to 1, the driver will attempt to set the voltage nearest to MIN_UV,
|
|
|
|
that is also lower than MAX_UV, during initialisation.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
If set to 0, MIN_UV and MAX_UV values will be ignored
|
|
|
|
during initialisation.
|
|
|
|
|
|
|
|
If the regulator is enabled here, and APPLY_UV=y, the board
|
|
|
|
voltage will actually change during initialisation.
|
|
|
|
|
|
|
|
If the regulator is not enabled here, and APPLY_UV=y, the
|
|
|
|
regulator voltage will be applied to the device in readiness for
|
|
|
|
the regulator being enabled later.
|
|
|
|
|
|
|
|
config ACT8945A_LDO1_MIN_UV
|
|
|
|
int "The minimum acceptable output voltage (600-3900mV)"
|
|
|
|
default 2500
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, the voltage nearest to this, and less than
|
|
|
|
MAX_UV will be applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO1_MAX_UV
|
|
|
|
int "The maximum acceptable output voltage (600-3900mV)"
|
|
|
|
default 2500
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, this is the maximum voltage that will be
|
|
|
|
applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO1_PULLDOWN
|
|
|
|
bool "Enable LDO1 pulldown when disabled"
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If enabled, the LDO output is discharged through a 1k5 resistor
|
|
|
|
when the LDO is in shutdown
|
|
|
|
|
|
|
|
endmenu # ACT8945A LDO Output 1 Configuration
|
|
|
|
|
|
|
|
menu "ACT8945A LDO Output 2 Configuration"
|
|
|
|
|
|
|
|
config ACT8945A_LDO2_NAME
|
|
|
|
string "LDO2 name"
|
|
|
|
default "ACT8945A_LDO2"
|
|
|
|
---help---
|
|
|
|
This is the name used for the ACT8945A LDO converter output 2.
|
|
|
|
It is used as the consumer name when you get or put a regulator.
|
|
|
|
|
|
|
|
config ACT8945A_LDO2_BOOT_ON
|
|
|
|
bool "Enable LDO2"
|
|
|
|
default y
|
|
|
|
|
|
|
|
config ACT8945A_LDO2_APPLY_UV
|
|
|
|
bool "Apply LDO2 new voltage at initialisation"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
If set to 1, the driver will attempt to set the voltage nearest to MIN_UV,
|
|
|
|
that is also lower than MAX_UV, during initialisation.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
If set to 0, MIN_UV and MAX_UV values will be ignored
|
|
|
|
during initialisation.
|
|
|
|
|
|
|
|
If the regulator is enabled here, and APPLY_UV=y, the board
|
|
|
|
voltage will actually change during initialisation.
|
|
|
|
|
|
|
|
If the regulator is not enabled here, and APPLY_UV=y, the
|
|
|
|
regulator voltage will be applied to the device in readiness for
|
|
|
|
the regulator being enabled later.
|
|
|
|
|
|
|
|
config ACT8945A_LDO2_MIN_UV
|
|
|
|
int "The minimum acceptable output voltage (600-3900mV)"
|
|
|
|
default 3300
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, the voltage nearest to this, and less than
|
|
|
|
MAX_UV will be applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO2_MAX_UV
|
|
|
|
int "The maximum acceptable output voltage (600-3900mV)"
|
|
|
|
default 3300
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, this is the maximum voltage that will be
|
|
|
|
applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO2_PULLDOWN
|
|
|
|
bool "Enable LDO2 pulldown when disabled"
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If enabled, the LDO output is discharged through a 1k5 resistor
|
|
|
|
when the LDO is in shutdown
|
|
|
|
|
|
|
|
endmenu # ACT8945A LDO Output 2 Configuration
|
|
|
|
|
|
|
|
menu "ACT8945A LDO Output 3 Configuration"
|
|
|
|
|
|
|
|
config ACT8945A_LDO3_NAME
|
|
|
|
string "LDO3 name"
|
|
|
|
default "ACT8945A_LDO3"
|
|
|
|
---help---
|
|
|
|
This is the name used for the ACT8945A LDO converter output 2.
|
|
|
|
It is used as the consumer name when you get or put a regulator.
|
|
|
|
|
|
|
|
config ACT8945A_LDO3_BOOT_ON
|
|
|
|
bool "Enable LDO3"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config ACT8945A_LDO3_APPLY_UV
|
|
|
|
bool "Apply LDO3 new voltage at initialisation"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
If set to 1, the driver will attempt to set the voltage nearest to MIN_UV,
|
|
|
|
that is also lower than MAX_UV, during initialisation.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
If set to 0, MIN_UV and MAX_UV values will be ignored
|
|
|
|
during initialisation.
|
|
|
|
|
|
|
|
If the regulator is enabled here, and APPLY_UV=y, the board
|
|
|
|
voltage will actually change during initialisation.
|
|
|
|
|
|
|
|
If the regulator is not enabled here, and APPLY_UV=y, the
|
|
|
|
regulator voltage will be applied to the device in readiness for
|
|
|
|
the regulator being enabled later.
|
|
|
|
|
|
|
|
config ACT8945A_LDO3_MIN_UV
|
|
|
|
int "The minimum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, the voltage nearest to this, and less than
|
|
|
|
MAX_UV will be applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO3_MAX_UV
|
|
|
|
int "The maximum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, this is the maximum voltage that will be
|
|
|
|
applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO3_PULLDOWN
|
|
|
|
bool "Enable LDO3 pulldown when disabled"
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If enabled, the LDO output is discharged through a 1k5 resistor
|
|
|
|
when the LDO is in shutdown
|
|
|
|
|
|
|
|
endmenu # ACT8945A LDO Output 3 Configuration
|
|
|
|
|
|
|
|
menu "ACT8945A LDO Output 4 Configuration"
|
|
|
|
|
|
|
|
config ACT8945A_LDO4_NAME
|
|
|
|
string "LDO4 name"
|
|
|
|
default "ACT8945A_LDO4"
|
|
|
|
---help---
|
|
|
|
This is the name used for the ACT8945A LDO converter output 2.
|
|
|
|
It is used as the consumer name when you get or put a regulator.
|
|
|
|
|
|
|
|
config ACT8945A_LDO4_BOOT_ON
|
|
|
|
bool "Enable LDO4"
|
|
|
|
default n
|
|
|
|
|
|
|
|
config ACT8945A_LDO4_APPLY_UV
|
|
|
|
bool "Apply LDO4 new voltage at initialisation"
|
|
|
|
default n
|
|
|
|
---help---
|
|
|
|
If set, the driver will attempt to set the voltage nearest to MIN_UV,
|
|
|
|
that is also lower than MAX_UV, during initialisation.
|
2023-02-25 19:14:11 +01:00
|
|
|
|
2023-01-11 17:57:16 +01:00
|
|
|
If not, MIN_UV and MAX_UV values will be ignored
|
|
|
|
during initialisation.
|
|
|
|
|
|
|
|
If the regulator is enabled here, and APPLY_UV=y, the board
|
|
|
|
voltage will actually change during initialisation.
|
|
|
|
|
|
|
|
If the regulator is not enabled here, and APPLY_UV=y, the
|
|
|
|
regulator voltage will be applied to the device in readiness for
|
|
|
|
the regulator being enabled later.
|
|
|
|
|
|
|
|
config ACT8945A_LDO4_MIN_UV
|
|
|
|
int "The minimum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If =1, the voltage nearest to this, and less than
|
|
|
|
MAX_UV will be applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO4_MAX_UV
|
|
|
|
int "The maximum acceptable output voltage (600-3900mV)"
|
|
|
|
default 600
|
|
|
|
range 600 3900
|
|
|
|
---help---
|
|
|
|
If APPLY_UV=Y, this is the maximum voltage that will be
|
|
|
|
applied during initialisation.
|
|
|
|
|
|
|
|
config ACT8945A_LDO4_PULLDOWN
|
|
|
|
bool "Enable LDO4 pulldown when disabled"
|
|
|
|
default y
|
|
|
|
---help---
|
|
|
|
If enabled, the LDO output is discharged through a 1k5 resistor
|
|
|
|
when the LDO is in shutdown
|
|
|
|
|
|
|
|
endmenu # ACT8945A LDO4 Configuration
|
|
|
|
|
|
|
|
endif # REGULATOR_ACT8945A
|
|
|
|
|
|
|
|
endif # REGULATOR
|
2022-08-01 11:31:49 +02:00
|
|
|
|
|
|
|
endmenu
|