Fix issue with LPC17xx CAN baud calculation
git-svn-id: svn://svn.code.sf.net/p/nuttx/code/trunk@4269 42af7a65-404d-4744-a932-0658087f49c3
This commit is contained in:
parent
f0a147e6e3
commit
046d315ba0
@ -700,10 +700,10 @@ Olimex LPC1766-STK Configuration Options
|
||||
CONFIG_CAN2_BAUD - CAN1 BAUD rate. Required if CONFIG_LPC17_CAN2 is defined.
|
||||
CONFIG_CAN1_DIVISOR - CAN1 is clocked at CCLK divided by this number.
|
||||
(the CCLK frequency is divided by this number to get the CAN clock).
|
||||
Default: 4
|
||||
Options = {1,2,4,6}. Default: 4.
|
||||
CONFIG_CAN2_DIVISOR - CAN2 is clocked at CCLK divided by this number.
|
||||
(the CCLK frequency is divided by this number to get the CAN clock).
|
||||
Default: 4
|
||||
Options = {1,2,4,6}. Default: 4.
|
||||
|
||||
LPC17xx specific PHY/Ethernet device driver settings. These setting
|
||||
also require CONFIG_NET and CONFIG_LPC17_ETHERNET.
|
||||
|