@ -898,6 +898,16 @@ Tickless OS
|
||||
CONFIG_SAMV7_TICKLESS_FREERUN=1 : Selects TC0 channel 1 for the free-
|
||||
: running timer
|
||||
|
||||
NOTE: In most cases, the slow clock will be used as the timer/counter
|
||||
input. The SAME70-Xplained board has pads for a 32.768KHz crystal,
|
||||
however, the boad ships with that position unpopulated. So, be default
|
||||
this will probably end up using the slow RC oscillator which will give
|
||||
you very bad timing.
|
||||
|
||||
If you add a crystal to your board, you can select to use it with the
|
||||
definition BOARD_HAVE_SLOWXTAL in the configs/same70-xplained/board.h
|
||||
file.
|
||||
|
||||
SAME70 Timer Usage
|
||||
------------------
|
||||
This current implementation uses two timers: A one-shot timer to
|
||||
|
@ -1471,7 +1471,7 @@ Tickless OS
|
||||
Configuration
|
||||
-------------
|
||||
The following configuration options will enable support for the Tickless
|
||||
OS for the SAMV7 platforms using TC0 channels 0-3 (other timers or
|
||||
OS for the SAMV7 platforms using TC0 channels 0-1 (other timers or
|
||||
timer channels could be used making the obvious substitutions):
|
||||
|
||||
RTOS Features -> Clocks and Timers
|
||||
@ -1490,10 +1490,8 @@ Tickless OS
|
||||
: running timer
|
||||
|
||||
NOTE: In most cases, the slow clock will be used as the timer/counter
|
||||
input. You should enable the 32.768KHz crystal for the slow clock by
|
||||
calling sam_sckc_enable(). Otherwise, you will be doing all system
|
||||
timing using the RC clock! UPDATE: This will now be selected by default
|
||||
when you configure for TICKLESS support.
|
||||
input. The 32.768KHz crystal is selected by the definition
|
||||
BOARD_HAVE_SLOWXTAL in the configs/samv71-xult/board.h file.
|
||||
|
||||
SAMV7 Timer Usage
|
||||
-----------------
|
||||
|