Merge branch 'ieee802154' of bitbucket.org:nuttx/nuttx into ieee802154
This commit is contained in:
commit
389144412c
@ -380,16 +380,24 @@ Configurations
|
||||
|
||||
NOTES:
|
||||
|
||||
1. This is another NSH example. If differs from the mrf24j40
|
||||
configuration in that this configuration, like the usbnsh
|
||||
configuration, it uses a USB serial device for console I/O.
|
||||
Such a configuration is useful on the Clicker2 STM32 which
|
||||
has no builtin RS-232 drivers and tangle of cables and jumpers
|
||||
needed to debug multi-board setups.
|
||||
1. This configuration differs from the mrf24j40-mac configuration in
|
||||
that this configuration, like the usbnsh configuration, uses a USB
|
||||
serial device for console I/O. Such a configuration is useful on the
|
||||
Clicker2 STM32 which has no builtin RS-232 drivers and eliminates the
|
||||
tangle of cables and jumpers needed to debug multi-board setups.
|
||||
|
||||
Other NOTES for the usbnsh configuration should appy.
|
||||
Most other NOTES for the usbnsh configuration should apply. Specific
|
||||
differences between the usbnsh or mrf24j40-mac configurations and this
|
||||
configuration are listed in these NOTES.
|
||||
|
||||
2. This configuration does NOT have USART3 output enabled. This
|
||||
2. On most serial terminal programs that I have used, the USB
|
||||
connection will be lost when the target board is reset. When that
|
||||
happens, you may have to reset your serial terminal program to adapt
|
||||
to the new USB connection. Using TeraTerm, I actually have to exit
|
||||
the serial program and restart it in order to detect and select the
|
||||
re-established USB serial connection.
|
||||
|
||||
3. This configuration does NOT have USART3 output enabled. This
|
||||
configuration supports logging of debug output to a circular
|
||||
buffer in RAM. This feature is discussed fully in this Wiki page: http://nuttx.org/doku.php?id=wiki:howtos:syslog . Relevant
|
||||
configuration settings are summarized below:
|
||||
@ -450,7 +458,14 @@ Configurations
|
||||
|
||||
NOTES:
|
||||
|
||||
1. This configuration does have USART3 output enabled and set up as
|
||||
1. One most serial terminal programs that I have used, the USB
|
||||
connection will be lost when the target board is reset. When that
|
||||
happens, you may have to reset your serial terminal program to adapt
|
||||
to the new USB connection. Using TeraTerm, I actually have to exit
|
||||
the serial program and restart it in order to detect and select the
|
||||
re-established USB serial connection.
|
||||
|
||||
2. This configuration does have USART3 output enabled and set up as
|
||||
the system logging device:
|
||||
|
||||
CONFIG_SYSLOG_CHAR=y : Use a character device for system logging
|
||||
@ -460,7 +475,7 @@ Configurations
|
||||
configuration so nothing should appear on USART3 unless you enable
|
||||
some debug output or enable the USB monitor.
|
||||
|
||||
2. Enabling USB monitor SYSLOG output. If tracing is enabled, the USB
|
||||
3. Enabling USB monitor SYSLOG output. If tracing is enabled, the USB
|
||||
device will save encoded trace output in in-memory buffer; if the
|
||||
USB monitor is enabled, that trace buffer will be periodically
|
||||
emptied and dumped to the system logging device (USART3 in this
|
||||
|
Loading…