``modbus`` FreeModBus port
|
||||
==========================
|
||||
|
||||
This directory contains a port of last open source version of FreeModBus (BSD
|
||||
license). The code in this directory is a subset of FreeModBus version 1.5.0
|
||||
(June 6, 2010) that can be downloaded in its entirety from
|
||||
http://developer.berlios.de/project/showfiles.php?group_id=6120.
|
||||
|
||||
Includes extensions to support RTU master mode by Armink(383016632@qq.com):
|
||||
https://github.com/armink/FreeModbus_Slave-Master-RTT-STM32. Ported to NuttX by
|
||||
Darcy Gong.
|
||||
|
||||
Directory Structure / Relation to freemodbus-v1.5.0
|
||||
---------------------------------------------------
|
||||
|
||||
The original FreeModBus download consists of several directories. This subset
|
||||
takes only the contents of one directory, ``modbus/``, that implements the core
|
||||
modbus logic and integrates that directory into the NuttX build system. The
|
||||
mapping between ``freemodbus-v1.5.0`` and the nuttx directories is shown below::
|
||||
|
||||
--------------------------- ----------------------------------------------
|
||||
freemodbus-v1.5.0 NuttX
|
||||
--------------------------- ----------------------------------------------
|
||||
All top level .txt files Not included
|
||||
demo/ Not included. This directory contains demo
|
||||
and porting code for a variety of platforms.
|
||||
The NuttX demo was ported from the LINUX
|
||||
demo in this directory and can be found at
|
||||
apps/examples/modbus.
|
||||
doc/ Not included. This directory contains Doxygen
|
||||
support files.
|
||||
modbus/ Included in its entirety in various locations:
|
||||
ascii apps/modbus/ascii
|
||||
functions apps/modbus/functions
|
||||
include apps/include/modbus
|
||||
mb.c apps/modbus/mb.c
|
||||
rtu apps/modbus/rtu
|
||||
tcp apps/modbus/tcp
|
||||
tools/ Not included. This directory contains Doxygen
|
||||
tools.
|
||||
--------------------------- ----------------------------------------------
|
||||
|
||||
So this directory is equivalent to the ``freemodbus-v1.5.0/modbus`` directory
|
||||
except that (1) it may include modifications for the integration with NuttX and
|
||||
(2) the modbus/include directory was moved to ``apps/modbus``.
|
||||
|
||||
The original, unmodified ``freemodbus-v1.5.0`` was checked in as SVN revision
|
||||
``4960``.
|
||||
|
||||
The other directory here, ``nuttx/``, implements the NuttX modbus interface. It
|
||||
derives from the ``freemodbus-v1.5.0/demo/LINUX/port`` directory.
|
||||
|
||||
Configuration Options
|
||||
---------------------
|
||||
|
||||
In the original ``freemodbus-v1.5.0`` release, the FreeModBus configuration was
|
||||
controlled by the header file ``mbconfig.h``. This header file was eliminated
|
||||
(post revision ``4960``) and the FreeModBus configuration was integrated into the
|
||||
NuttX configuration system.
|
||||
|
||||
The NuttX-named configuration options that are available include:
|
||||
|
||||
- ``CONFIG_MODBUS`` – General ModBus support.
|
||||
- ``CONFIG_MB_ASCII_ENABLED`` – Modbus ASCII support.
|
||||
- ``CONFIG_MB_ASCII_MASTER`` – Modbus ASCII master support.
|
||||
- ``CONFIG_MB_RTU_ENABLED`` – Modbus RTU support.
|
||||
- ``CONFIG_MB_RTU_MASTER`` – Modbus RTU master support.
|
||||
- ``CONFIG_MB_TCP_ENABLED`` – Modbus TCP support.
|
||||
- ``CONFIG_MB_ASCII_TIMEOUT_SEC`` – Character timeout value for Modbus ASCII. The
|
||||
character timeout value is not fixed for Modbus ASCII and is therefore a
|
||||
configuration option. It should be set to the maximum expected delay time of
|
||||
the network. Default: ``1``.
|
||||
- ``CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS`` – Timeout to wait in ASCII prior
|
||||
to enabling transmitter. If defined the function calls ``vMBPortSerialDelay``
|
||||
with the argument ``CONFIG_MB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS`` to allow for a
|
||||
delay before the serial transmitter is enabled. This is required because some
|
||||
targets are so fast that there is no time between receiving and transmitting
|
||||
the frame. If the master is too slow with enabling its receiver then it will
|
||||
not receive the response correctly.
|
||||
- ``CONFIG_MB_FUNC_HANDLERS_MAX`` – Maximum number of Modbus functions codes the
|
||||
protocol stack should support. The maximum number of supported Modbus
|
||||
functions must be greater than the sum of all enabled functions in this file
|
||||
and custom function handlers. If set too small, adding more functions will
|
||||
fail.
|
||||
- ``CONFIG_MB_FUNC_OTHER_REP_SLAVEID_BUF`` – Number of bytes which should be
|
||||
allocated for the Report Slave ID command. This number limits the maximum size
|
||||
of the additional segment in the report slave id function. See
|
||||
``eMBSetSlaveID()`` for more information on how to set this value. It is only
|
||||
used if ``CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED`` is set to ``1``.
|
||||
- ``CONFIG_MB_FUNC_OTHER_REP_SLAVEID_ENABLED`` – If the Report Slave ID function
|
||||
should be enabled.
|
||||
- ``CONFIG_MB_FUNC_READ_INPUT_ENABLED`` – If the Read Input Registers function
|
||||
should be enabled.
|
||||
- ``CONFIG_MB_FUNC_READ_HOLDING_ENABLED`` – If the Read Holding Registers function
|
||||
should be enabled.
|
||||
- ``CONFIG_MB_FUNC_WRITE_HOLDING_ENABLED`` – If the Write Single Register function
|
||||
should be enabled.
|
||||
- ``CONFIG_MB_FUNC_WRITE_MULTIPLE_HOLDING_ENABLED`` – If the Write Multiple
|
||||
registers function should be enabled.
|
||||
- ``CONFIG_MB_FUNC_READ_COILS_ENABLED`` – If the Read Coils function should be
|
||||
enabled.
|
||||
- ``CONFIG_MB_FUNC_WRITE_COIL_ENABLED`` – If the Write Coils function should be
|
||||
enabled.
|
||||
- ``CONFIG_MB_FUNC_WRITE_MULTIPLE_COILS_ENABLED`` – If the Write Multiple Coils
|
||||
function should be enabled.
|
||||
- ``CONFIG_MB_FUNC_READ_DISCRETE_INPUTS_ENABLED`` – If the Read Discrete Inputs
|
||||
function should be enabled.
|
||||
- ``CONFIG_MB_FUNC_READWRITE_HOLDING_ENABLED`` – If the Read/Write Multiple
|
||||
Registers function should be enabled.
|
||||
|
||||
See also other serial settings, in particular:
|
||||
|
||||
- ``CONFIG_SERIAL_TERMIOS`` – Serial driver supports ``termios.h`` interfaces
|
||||
If this is not defined, then the terminal settings (baud, parity, etc.)
|
||||
are not configurable at runtime.
|
||||
|
||||
Note
|
||||
----
|
||||
|
||||
The developer of FreeModBus, Christian Walter, is still developing Modbus
|
||||
libraries, although they are now commercial. See
|
||||
http://www.embedded-solutions.at/ for further information.
|