SAMA5D4 EMAC: Add a kludge to work around a suspected hardware issue
This commit is contained in:
parent
46bde6e716
commit
c95a5924c9
@ -1124,6 +1124,9 @@ Networking
|
||||
configuration options. The SAMA5D44 supports two different 10/100Base-T
|
||||
Ethernet MAC peripherals.
|
||||
|
||||
NOTE: See the "kludge" for EMAC that is documented in the To-Do
|
||||
list at the end of this README file.
|
||||
|
||||
------------------------------ ------------------- -------------------------
|
||||
SAMA5D4 PIO SAMA5D4-MB KSZ8081RNB
|
||||
------------------------------ ------------------- -------------------------
|
||||
@ -3392,6 +3395,9 @@ Configurations
|
||||
large if no network is attached (A production design would bring up
|
||||
the network asynchronously to avoid these start up delays).
|
||||
|
||||
See the "kludge" for EMAC that is documented in the To-Do list at
|
||||
the end of this README file.
|
||||
|
||||
12. The SAMA5D4-EK includes for an AT25 serial DataFlash. That support is
|
||||
NOT enabled in this configuration. Support for that serial FLASH can
|
||||
be enabled by modifying the NuttX configuration as described above in
|
||||
@ -3492,7 +3498,37 @@ To-Do List
|
||||
Also, we should be receiving interrupts when an SD card is inserted or
|
||||
removed; we are not.
|
||||
|
||||
4) Some drivers may require some adjustments if you intend to run from SDRAM.
|
||||
4) There is a kludge in place in the Ethernet code to work around a problem
|
||||
that I see. The problem that I see is as follows:
|
||||
|
||||
a. To send packets, the software keeps a queue of TX descriptors in
|
||||
memory.
|
||||
|
||||
b. When a packet is ready to be sent, the software clears bit 31 of a
|
||||
status word in the descriptor meaning that the descriptor now
|
||||
"belongs" to the hardware.
|
||||
|
||||
c. The hardware sets bit 31 in memory when the transfer completes.
|
||||
|
||||
The problem that I see is that:
|
||||
|
||||
d. Occasionally bit 31 of the status word is not cleared even though
|
||||
the Ethernet packet was successfully sent.
|
||||
|
||||
Since the software does not see bit 31 set, it seems like the transfer
|
||||
did not complete and the Ethernet locks up.
|
||||
|
||||
The workaround/kludge that is in place makes this assumption: If an
|
||||
Ethernet transfer complete interrupt is received, then at least one
|
||||
packet must have completed. In this case, the software ignores
|
||||
checking the USED bit for one packet.
|
||||
|
||||
With this kludge in place, the driver appears to work fine. However,
|
||||
there is a danger to what I have done: If a spurious interrupt
|
||||
occurs, than the USED bit would not be set and the transfer would be
|
||||
lost.
|
||||
|
||||
5) Some drivers may require some adjustments if you intend to run from SDRAM.
|
||||
That is because in this case macros like BOARD_MCK_FREQUENCY are not constants
|
||||
but are instead function calls: The MCK clock frequency is not known in
|
||||
advance but instead has to be calculated from the bootloader PLL configuration.
|
||||
|