configs/sama5d3x-ek: Fix some typos
This commit is contained in:
parent
a0b330bd92
commit
d204310623
@ -460,7 +460,7 @@ Buttons and LEDs
|
||||
Only the momentary push button is controllable by software (labeled
|
||||
"PB_USER1" on the board):
|
||||
|
||||
- PE27. Pressing the switch connect PE27 to grounded. Therefore, PE27
|
||||
- PE27. Pressing the switch connects PE27 to grounded. Therefore, PE27
|
||||
must be pulled high internally. When the button is pressed the SAMA5
|
||||
will sense "0" is on PE27.
|
||||
|
||||
@ -566,11 +566,11 @@ Networking
|
||||
System Type -> EMAC device driver options
|
||||
CONFIG_SAMA5_EMAC_NRXBUFFERS=16 : Set aside some RS and TX buffers
|
||||
CONFIG_SAMA5_EMAC_NTXBUFFERS=4
|
||||
CONFIG_SAMA5_EMAC_PHYADDR=1 : KSZ8051 PHY is at address 1
|
||||
CONFIG_SAMA5_EMAC_PHYADDR=1 : KSZ8021/31 PHY is at address 1
|
||||
CONFIG_SAMA5_EMAC_AUTONEG=y : Use autonegotiation
|
||||
CONFIG_SAMA5_EMAC_RMII=y : Either MII or RMII interface should work
|
||||
CONFIG_SAMA5_EMAC_PHYSR=30 : Address of PHY status register on KSZ8051
|
||||
CONFIG_SAMA5_EMAC_PHYSR_ALTCONFIG=y : Needed for KSZ8051
|
||||
CONFIG_SAMA5_EMAC_PHYSR=30 : Address of PHY status register on KSZ8021/31
|
||||
CONFIG_SAMA5_EMAC_PHYSR_ALTCONFIG=y : Needed for KSZ8021/31
|
||||
CONFIG_SAMA5_EMAC_PHYSR_ALTMODE=0x7 : " " " " " "
|
||||
CONFIG_SAMA5_EMAC_PHYSR_10HD=0x1 : " " " " " "
|
||||
CONFIG_SAMA5_EMAC_PHYSR_100HD=0x2 : " " " " " "
|
||||
@ -578,7 +578,7 @@ Networking
|
||||
CONFIG_SAMA5_EMAC_PHYSR_100FD=0x6 : " " " " " "
|
||||
|
||||
PHY selection. Later in the configuration steps, you will need to select
|
||||
the KSZ8051 PHY for EMAC (See below)
|
||||
the KSZ8021/31 PHY for EMAC (See below)
|
||||
|
||||
Selecting the GMAC peripheral
|
||||
-----------------------------
|
||||
@ -622,7 +622,7 @@ Networking
|
||||
Device drivers -> Network Device/PHY Support
|
||||
CONFIG_NETDEVICES=y : Enabled PHY selection
|
||||
CONFIG_ETH0_PHY_KSZ8051=y : Select the KSZ8051 PHY (for EMAC), OR
|
||||
CONFIG_ETH0_PHY_KSZ90x1=y : Select teh KSZ9021/31 PHY (for GMAC)
|
||||
CONFIG_ETH0_PHY_KSZ90x1=y : Select the KSZ9021/31 PHY (for GMAC)
|
||||
|
||||
Application Configuration -> Network Utilities
|
||||
CONFIG_NETUTILS_RESOLV=y : Enable host address resolution
|
||||
@ -812,7 +812,7 @@ HSMCI Card Slots
|
||||
labelled MCI1).
|
||||
|
||||
The full size SD card slot connects via HSMCI0. The card detect discrete
|
||||
is available on PB17 (pulled high). The write protect discrete is tied to
|
||||
is available on PD17 (pulled high). The write protect discrete is tied to
|
||||
ground (via PP6) and not available to software. The slot supports 8-bit
|
||||
wide transfer mode, but the NuttX driver currently uses only the 4-bit
|
||||
wide transfer mode
|
||||
@ -830,7 +830,7 @@ HSMCI Card Slots
|
||||
PD0 MCI0_CDA
|
||||
|
||||
The microSD connects vi HSMCI1. The card detect discrete is available on
|
||||
PB18 (pulled high):
|
||||
PD18 (pulled high):
|
||||
|
||||
PD18 MCI1_CD
|
||||
PB20 MCI1_DA0
|
||||
|
@ -151,7 +151,7 @@
|
||||
* 3. One User momentary Push Button
|
||||
* 4. One Disable CS Push Button
|
||||
*
|
||||
* Only the momentary push button is controllable by software (labeled
|
||||
* Only the momentary push button is controllable by software (labelled
|
||||
* "PB_USER1" on the board):
|
||||
*
|
||||
* - PE27. Pressing the switch connect PE27 to grounded. Therefore, PE27
|
||||
@ -327,7 +327,7 @@ extern "C" {
|
||||
*
|
||||
* Description:
|
||||
* All SAMA5 architectures must provide the following entry point. This entry point
|
||||
* is called early in the intitialization -- after all memory has been configured
|
||||
* is called early in the initialization -- after all memory has been configured
|
||||
* and mapped but before any devices have been initialized.
|
||||
*
|
||||
************************************************************************************/
|
||||
|
@ -368,7 +368,7 @@
|
||||
* Only the momentary push button is controllable by software (labeled
|
||||
* "PB_USER1" on the board):
|
||||
*
|
||||
* - PE27. Pressing the switch connect PE27 to grounded. Therefore, PE27
|
||||
* - PE27. Pressing the switch connects PE27 to ground. Therefore, PE27
|
||||
* must be pulled high internally. When the button is pressed the SAMA5
|
||||
* will sense "0" is on PE27.
|
||||
*/
|
||||
|
Loading…
Reference in New Issue
Block a user