# # For a description of the syntax of this configuration file, # see the file kconfig-language.txt in the NuttX tools repository. # menu "Power Supply Support" config DRIVERS_POWERLED bool "High Power LED driver" default n ---help--- Enables building of an powerled upper half driver. menuconfig DRIVERS_SMPS bool "Switched-Mode Power Supply (SMPS)" default n ---help--- Enables building of an SMPS upper half driver. if DRIVERS_SMPS config SMPS_HAVE_OUTPUT_VOLTAGE bool "Have Output Voltage" default n config SMPS_HAVE_OUTPUT_CURRENT bool "Have Output Current" default n config SMPS_HAVE_OUTPUT_POWER bool "Have Output Power" default n config SMPS_HAVE_INPUT_VOLTAGE bool "Have Input Voltage" default n config SMPS_HAVE_INPUT_CURRENT bool "Have Input Current" default n config SMPS_HAVE_INPUT_POWER bool "Have Input Power" default n config SMPS_HAVE_EFFICIENCY bool "Have Power Efficiency" default n endif config REGULATOR bool "Regulator core driver support" default n ---help--- The regulator core driver implements the upper layer framework that the lower layer driver can register with, and the common regulator APIs that are easy for other drivers to call for the control of their power supply. if REGULATOR config REGULATOR_GPIO bool "Regulator gpio driver support" default n ---help--- The regulator gpio driver implements the lower regulator ops that use gpio to control to regulator. config REGULATOR_RPMSG bool "Regulator RPMSG driver support" depends on RPTUN default n ---help--- The RPMSG regulator driver implements the common regulator APIs, inside which the regulator operations are sent from the client to the remote device via the RPMSG channel. The remote device(namely server) is responsible for the parse and the completion. menuconfig REGULATOR_ACT8945A bool "Qorvo ACT8945A regulator support - MAKE CHANGES WITH CARE" default n ---help--- ----------------------------------------------------------------------- TAKE GREAT CARE - BOARD DAMAGE MAY RESULT FROM INNAPPROPIATE CHANGES ----------------------------------------------------------------------- The ACT8945A regulator driver implements the lower regulator ops thats use I2C to control the regulator functions. if REGULATOR_ACT8945A menu "ACT8945A Regulator System Functions" choice prompt "ACT8945A SYSLEV threshold" default ACT8945A_SYSLEV_3000 ---help--- The SYSLEV voltage below which the configured SYSLEV mode will be triggered. config ACT8945A_SYSLEV_2300 bool "2.3V" config ACT8945A_SYSLEV_2400 bool "2.4V" config ACT8945A_SYSLEV_2500 bool "2.5" config ACT8945A_SYSLEV_2600 bool "2.6V" config ACT8945A_SYSLEV_2700 bool "2.7V" config ACT8945A_SYSLEV_2800 bool "2.8V" config ACT8945A_SYSLEV_2900 bool "2.9V" config ACT8945A_SYSLEV_3000 bool "3.0V" config ACT8945A_SYSLEV_3100 bool "3.1V" config ACT8945A_SYSLEV_3200 bool "3.2V" config ACT8945A_SYSLEV_3300 bool "3.3V" config ACT8945A_SYSLEV_3400 bool "3.4V" config ACT8945A_SYSLEV_3500 bool "3.5V" config ACT8945A_SYSLEV_3600 bool "3.6V" config ACT8945A_SYSLEV_3700 bool "3.7V" config ACT8945A_SYSLEV_3800 bool "3.8V" endchoice # ACT8945A SYSLEV threshold choice prompt "ACT8945A SYSLEV mode" default ACT8945A_SYSLEV_MODE_INTERRUPT ---help--- Determines the response to the SYSLEV voltage detector - Generate an interrupt when Vsys < SYSLEV threshold, or - Automatic shutdown when Vsys < SYSLEV threshold config ACT8945A_SYSLEV_MODE_INTERRUPT bool "Interrupt" ---help--- Generates an interrupt when Vsys < SYSLEV threshold. Selecting this will unmask the SYSLEV interrupt as well. config ACT8945A_SYSLEV_MODE_SHUTDOWN bool "Shutdown" ---help--- Automatic shutdown when Vsys < SYSLEV threshold endchoice # ACT8945A_SYSLEV_MODE choice prompt "ACT8945A Reset Timer Setting" default ACT8945A_TRST_64 ---help--- Defines the reset timeout threshold. config ACT8945A_TRST_64 bool "64ms" config ACT8945A_TRST_260 bool "260ms" endchoice # ACT8945A Reset Timer Setting endmenu # ACT8945A System Functions menu "ACT8945A DCDC1 Configuration" config ACT8945A_DCDC1_NAME string "DCDC1 name" default "ACT8945A_DCDC1" ---help--- This is the name used for the ACT8945A DCDC converter output 1. It is used as the consumer name when you get or put a regulator. config ACT8945A_DCDC1_BOOT_ON bool "Enable DCDC1" default y config ACT8945A_DCDC1_APPLY_UV bool "Apply DCDC1 new voltage at initialisation" default n ---help--- If set, the driver will attempt to set the voltage nearest to MIN_UV, that is also lower than MAX_UV, during initialisation. If not set, MIN_UV and MAX_UV values will be ignored during initialisation. If the regulator is enabled here, and APPLY_UV=y, the board voltage will actually change during initialisation. If the regulator is not enabled here, and APPLY_UV=y, the regulator voltage will be applied to the device in readiness for the regulator being enabled later. DO NOT CHANGE THIS UNLESS YOU KNOW WHAT YOU ARE DOING! It is usually a critical processor voltage rail. config ACT8945A_DCDC1_MIN_UV int "The minimum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If APPLY_UV=Y, the voltage nearest to this, and less than MAX_UV will be applied during initialisation. config ACT8945A_DCDC1_MAX_UV int "The maximum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If APPLY_UV=Y, this is the maximum voltage that will be applied during initialisation. endmenu # ACT8945A DCDC1 Configuration menu "ACT8945A DCDC2 Configuration" config ACT8945A_DCDC2_NAME string "DCDC2 name" default "ACT8945A_DCDC2" ---help--- This is the name used for the ACT8945A DCDC converter output 2. It is used as the consumer name when you get or put a regulator. config ACT8945A_DCDC2_BOOT_ON bool "Enable DCDC2" default y config ACT8945A_DCDC2_APPLY_UV bool "Apply DCDC2 new voltage at initialisation" default n ---help--- If set, the driver will attempt to set the voltage nearest to MIN_UV, that is also lower than MAX_UV, during initialisation. If not set, MIN_UV and MAX_UV values will be ignored during initialisation. If the regulator is enabled here, and APPLY_UV=y, the board voltage will actually change during initialisation. If the regulator is not enabled here, and APPLY_UV=Y, the regulator voltage will be applied to the device in readiness for the regulator being enabled later. DO NOT CHANGE THIS UNLESS YOU KNOW WHAT YOU ARE DOING! It is usually a critical processor voltage rail. config ACT8945A_DCDC2_MIN_UV int "The minimum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If APPLY_UV=Y, the voltage nearest to this, and less than MAX_UV will be applied during initialisation. config ACT8945A_DCDC2_MAX_UV int "The maximum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If APPLY_UV=Y, this is the maximum voltage that will be applied during initialisation. endmenu # ACT8945A DCDC2 Configuration menu "ACT8945A DCDC3 Configuration" config ACT8945A_DCDC3_NAME string "DCDC3 name" default "ACT8945A_DCDC3" ---help--- This is the name used for the ACT8945A DCDC converter output 3. It is used as the consumer name when you get or put a regulator. config ACT8945A_DCDC3_BOOT_ON bool "Enable DCDC3" default y config ACT8945A_DCDC3_APPLY_UV bool "Apply DCDC3 new voltage at initialisation" default n ---help--- If set to 1, the driver will attempt to set the voltage nearest to MIN_UV, that is also lower than MAX_UV, during initialisation. If set to 0, MIN_UV and MAX_UV values will be ignored during initialisation. If the regulator is enabled here, and APPLY_UV=y, the board voltage will actually change during initialisation. If the regulator is not enabled here, and APPLY_UV=y, the regulator voltage will be applied to the device in readiness for the regulator being enabled later. DO NOT CHANGE THIS UNLESS YOU KNOW WHAT YOU ARE DOING! It is usually a critical processor voltage rail. config ACT8945A_DCDC3_MIN_UV int "The minimum acceptable output voltage (600-3900mV)" default 3300 range 600 3900 ---help--- If APPLY_UV=Y, the voltage nearest to this, and less than MAX_UV will be applied during initialisation. config ACT8945A_DCDC3_MAX_UV int "The maximum acceptable output voltage (600-3900mV)" default 3300 range 600 3900 ---help--- If APPLY_UV=Y, this is the maximum voltage that will be applied during initialisation. endmenu # ACT8945A DCDC 3 Configuration menu "ACT8945A LDO Output 1 Configuration" config ACT8945A_LDO1_NAME string "LDO1 name" default "ACT8945A_LDO1" ---help--- This is the name used for the ACT8945A LDO converter output 1. It is used as the consumer name when you get or put a regulator. config ACT8945A_LDO1_BOOT_ON bool "Enable LDO1" default y config ACT8945A_LDO1_APPLY_UV bool "Apply LDO1 new voltage at initialisation" default n ---help--- If set to 1, the driver will attempt to set the voltage nearest to MIN_UV, that is also lower than MAX_UV, during initialisation. If set to 0, MIN_UV and MAX_UV values will be ignored during initialisation. If the regulator is enabled here, and APPLY_UV=y, the board voltage will actually change during initialisation. If the regulator is not enabled here, and APPLY_UV=y, the regulator voltage will be applied to the device in readiness for the regulator being enabled later. config ACT8945A_LDO1_MIN_UV int "The minimum acceptable output voltage (600-3900mV)" default 2500 range 600 3900 ---help--- If APPLY_UV=Y, the voltage nearest to this, and less than MAX_UV will be applied during initialisation. config ACT8945A_LDO1_MAX_UV int "The maximum acceptable output voltage (600-3900mV)" default 2500 range 600 3900 ---help--- If APPLY_UV=Y, this is the maximum voltage that will be applied during initialisation. config ACT8945A_LDO1_PULLDOWN bool "Enable LDO1 pulldown when disabled" default y ---help--- If enabled, the LDO output is discharged through a 1k5 resistor when the LDO is in shutdown endmenu # ACT8945A LDO Output 1 Configuration menu "ACT8945A LDO Output 2 Configuration" config ACT8945A_LDO2_NAME string "LDO2 name" default "ACT8945A_LDO2" ---help--- This is the name used for the ACT8945A LDO converter output 2. It is used as the consumer name when you get or put a regulator. config ACT8945A_LDO2_BOOT_ON bool "Enable LDO2" default y config ACT8945A_LDO2_APPLY_UV bool "Apply LDO2 new voltage at initialisation" default n ---help--- If set to 1, the driver will attempt to set the voltage nearest to MIN_UV, that is also lower than MAX_UV, during initialisation. If set to 0, MIN_UV and MAX_UV values will be ignored during initialisation. If the regulator is enabled here, and APPLY_UV=y, the board voltage will actually change during initialisation. If the regulator is not enabled here, and APPLY_UV=y, the regulator voltage will be applied to the device in readiness for the regulator being enabled later. config ACT8945A_LDO2_MIN_UV int "The minimum acceptable output voltage (600-3900mV)" default 3300 range 600 3900 ---help--- If APPLY_UV=Y, the voltage nearest to this, and less than MAX_UV will be applied during initialisation. config ACT8945A_LDO2_MAX_UV int "The maximum acceptable output voltage (600-3900mV)" default 3300 range 600 3900 ---help--- If APPLY_UV=Y, this is the maximum voltage that will be applied during initialisation. config ACT8945A_LDO2_PULLDOWN bool "Enable LDO2 pulldown when disabled" default y ---help--- If enabled, the LDO output is discharged through a 1k5 resistor when the LDO is in shutdown endmenu # ACT8945A LDO Output 2 Configuration menu "ACT8945A LDO Output 3 Configuration" config ACT8945A_LDO3_NAME string "LDO3 name" default "ACT8945A_LDO3" ---help--- This is the name used for the ACT8945A LDO converter output 2. It is used as the consumer name when you get or put a regulator. config ACT8945A_LDO3_BOOT_ON bool "Enable LDO3" default n config ACT8945A_LDO3_APPLY_UV bool "Apply LDO3 new voltage at initialisation" default n ---help--- If set to 1, the driver will attempt to set the voltage nearest to MIN_UV, that is also lower than MAX_UV, during initialisation. If set to 0, MIN_UV and MAX_UV values will be ignored during initialisation. If the regulator is enabled here, and APPLY_UV=y, the board voltage will actually change during initialisation. If the regulator is not enabled here, and APPLY_UV=y, the regulator voltage will be applied to the device in readiness for the regulator being enabled later. config ACT8945A_LDO3_MIN_UV int "The minimum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If APPLY_UV=Y, the voltage nearest to this, and less than MAX_UV will be applied during initialisation. config ACT8945A_LDO3_MAX_UV int "The maximum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If APPLY_UV=Y, this is the maximum voltage that will be applied during initialisation. config ACT8945A_LDO3_PULLDOWN bool "Enable LDO3 pulldown when disabled" default y ---help--- If enabled, the LDO output is discharged through a 1k5 resistor when the LDO is in shutdown endmenu # ACT8945A LDO Output 3 Configuration menu "ACT8945A LDO Output 4 Configuration" config ACT8945A_LDO4_NAME string "LDO4 name" default "ACT8945A_LDO4" ---help--- This is the name used for the ACT8945A LDO converter output 2. It is used as the consumer name when you get or put a regulator. config ACT8945A_LDO4_BOOT_ON bool "Enable LDO4" default n config ACT8945A_LDO4_APPLY_UV bool "Apply LDO4 new voltage at initialisation" default n ---help--- If set, the driver will attempt to set the voltage nearest to MIN_UV, that is also lower than MAX_UV, during initialisation. If not, MIN_UV and MAX_UV values will be ignored during initialisation. If the regulator is enabled here, and APPLY_UV=y, the board voltage will actually change during initialisation. If the regulator is not enabled here, and APPLY_UV=y, the regulator voltage will be applied to the device in readiness for the regulator being enabled later. config ACT8945A_LDO4_MIN_UV int "The minimum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If =1, the voltage nearest to this, and less than MAX_UV will be applied during initialisation. config ACT8945A_LDO4_MAX_UV int "The maximum acceptable output voltage (600-3900mV)" default 600 range 600 3900 ---help--- If APPLY_UV=Y, this is the maximum voltage that will be applied during initialisation. config ACT8945A_LDO4_PULLDOWN bool "Enable LDO4 pulldown when disabled" default y ---help--- If enabled, the LDO output is discharged through a 1k5 resistor when the LDO is in shutdown endmenu # ACT8945A LDO4 Configuration endif # REGULATOR_ACT8945A endif # REGULATOR endmenu