2013-07-13 21:19:15 +02:00
|
|
|
README
|
|
|
|
======
|
|
|
|
|
2013-07-16 16:26:59 +02:00
|
|
|
Contents
|
|
|
|
========
|
|
|
|
|
|
|
|
o Buffering Notes
|
|
|
|
- Hardware Flow Control
|
|
|
|
- RX Buffer Size
|
|
|
|
- Buffer Recommendations
|
|
|
|
o Using NuttX Zmodem with a Linux Host
|
|
|
|
- Sending Files from the Target to the Linux Host PC
|
|
|
|
- Receiving Files on the Target from the Linux Host PC
|
|
|
|
o Building the Zmodem Tools to Run Under Linux
|
|
|
|
o Status
|
|
|
|
|
2013-07-15 20:33:35 +02:00
|
|
|
Buffering Notes
|
|
|
|
===============
|
|
|
|
|
|
|
|
Hardware Flow Control
|
|
|
|
---------------------
|
|
|
|
Hardware flow control must be enabled in serial drivers in order to
|
|
|
|
prevent data overrun. However, in the most NuttX serial drivers, hardware
|
|
|
|
flow control only protects the hardware RX FIFO: Data will not be lost in
|
|
|
|
the hardware FIFO but can still be lost when it is taken from the FIFO.
|
|
|
|
We can still overflow the serial driver's RX buffer even with hardware
|
|
|
|
flow control enabled! That is probably a bug. But the workaround solution
|
|
|
|
that I have used is to use lower data rates and a large serial driver RX
|
|
|
|
buffer.
|
|
|
|
|
|
|
|
Those measures should be unnecessary if buffering and hardware flow
|
|
|
|
control are set up and working correctly.
|
|
|
|
|
|
|
|
RX Buffer Size
|
|
|
|
--------------
|
|
|
|
The Zmodem protocol supports a message that informs the file sender of
|
|
|
|
the maximum size of dat that you can buffer (ZRINIT). However, my
|
|
|
|
experience is that the Linux sz ignores this setting and always sends file
|
|
|
|
data at the maximum size (1024) no matter what size of buffer you report.
|
|
|
|
That is unfortunate because that, combined with the possibilities of data
|
|
|
|
overrun mean that you must use quite large buffering for Zmodem file
|
|
|
|
receipt to be reliable (none of these issues effect sending of files).
|
|
|
|
|
|
|
|
Buffer Recommendations
|
|
|
|
----------------------
|
|
|
|
Based on the limitations of NuttX hardware flow control and of the Linux
|
|
|
|
sz behavior, I have been testing with the following configuration
|
|
|
|
(assuming UART1 is the Zmodem device):
|
|
|
|
|
|
|
|
1) This setting determines that maximum size of a data packet frame:
|
|
|
|
|
|
|
|
CONFIG_SYSTEM_ZMODEM_PKTBUFSIZE=1024
|
|
|
|
|
|
|
|
2) Input Buffering. If the input buffering is set to a full frame, then
|
|
|
|
data overflow is less likely.
|
|
|
|
|
|
|
|
CONFIG_UART1_RXBUFSIZE=1024
|
|
|
|
|
|
|
|
3) With a larger driver input buffer, the Zmodem receive I/O buffer can be
|
|
|
|
smaller:
|
|
|
|
|
|
|
|
CONFIG_SYSTEM_ZMODEM_RCVBUFSIZE=256
|
|
|
|
|
|
|
|
4) Output buffering. Overrun cannot occur on output (on the NuttX side)
|
|
|
|
so there is no need to be so careful:
|
|
|
|
|
|
|
|
CONFIG_SYSTEM_ZMODEM_SNDBUFSIZE=512
|
|
|
|
CONFIG_UART1_TXBUFSIZE=256
|
|
|
|
|
2013-07-13 21:19:15 +02:00
|
|
|
Using NuttX Zmodem with a Linux Host
|
|
|
|
====================================
|
|
|
|
|
2013-07-14 20:34:45 +02:00
|
|
|
Sending Files from the Target to the Linux Host PC
|
|
|
|
--------------------------------------------------
|
2013-07-13 21:19:15 +02:00
|
|
|
The NuttX Zmodem commands have been verified against the rzsz programs
|
|
|
|
running on a Linux PC. To send a file to the PC, first make sure that
|
2013-07-15 20:33:35 +02:00
|
|
|
the serial port is configured to work with the board (Assuming you are
|
|
|
|
using 9600 baud for the data transfers -- high rates may result in data
|
|
|
|
overruns):
|
2013-07-13 21:19:15 +02:00
|
|
|
|
2013-07-15 20:33:35 +02:00
|
|
|
$ sudo stty -F /dev/ttyS0 9600 # Select 9600 BAUD
|
2013-07-16 19:23:35 +02:00
|
|
|
$ sudo stty -F /dev/ttyS0 crtscts # Enables CTS/RTS handshaking *
|
2013-07-15 20:33:35 +02:00
|
|
|
$ sudo stty -F /dev/ttyS0 # Show the TTY configuration
|
2013-07-13 21:19:15 +02:00
|
|
|
|
2013-07-16 19:23:35 +02:00
|
|
|
* Only is hardware flow control is enabled.
|
|
|
|
|
2013-07-15 20:33:35 +02:00
|
|
|
Start rz on the Linux host (using /dev/ttyS0 as an example):
|
2013-07-13 21:19:15 +02:00
|
|
|
|
|
|
|
$ sudo rz </dev/ttyS0 >/dev/ttyS0
|
|
|
|
|
|
|
|
You can add the rz -v option multiple times, each increases the level
|
|
|
|
of debug output. If you want to capture the Linux rz output, then
|
|
|
|
re-direct stderr to a log file by adding 2>rz.log to the end of the
|
|
|
|
rz command.
|
|
|
|
|
|
|
|
NOTE: The NuttX Zmodem does sends rz\n when it starts in compliance with
|
|
|
|
the Zmodem specification. On Linux this, however, seems to start some
|
|
|
|
other, incompatible version of rz. You need to start rz manually to
|
|
|
|
make sure that the correct version is selected. You can tell when this
|
|
|
|
evil rz/sz has inserted itself because you will see the '^' (0x5e)
|
|
|
|
character replacing the standard Zmodem ZDLE character (0x19) in the
|
|
|
|
binary data stream.
|
|
|
|
|
|
|
|
If you don't have the rz command on your Linux box, the package to
|
|
|
|
install rzsz (or possibily lrzsz).
|
|
|
|
|
2013-07-15 20:33:35 +02:00
|
|
|
Then on the target (using /dev/ttyS1 as an example).
|
2013-07-13 21:19:15 +02:00
|
|
|
|
|
|
|
> sz -d /dev/ttyS1 <filename>
|
|
|
|
|
|
|
|
Where filename is the full path to the file to send (i.e., it begins
|
2013-07-15 20:33:35 +02:00
|
|
|
with the '/' character). /dev/ttyS1 or whatever device you select
|
|
|
|
*MUST* support Hardware flow control in order to throttle therates of
|
|
|
|
data transfer to fit within the allocated buffers.
|
2013-07-13 21:19:15 +02:00
|
|
|
|
2013-07-14 20:34:45 +02:00
|
|
|
Receiving Files on the Target from the Linux Host PC
|
|
|
|
----------------------------------------------------
|
2013-07-16 19:23:35 +02:00
|
|
|
NOTE: There are issues with using the Linux sz command with the NuttX
|
|
|
|
rz command. See "Status" below. It is recommended that you use the
|
|
|
|
NuttX sz command on Linux as described in the next paragraph.
|
|
|
|
|
2013-07-14 20:34:45 +02:00
|
|
|
To send a file to the target, first make sure that the serial port on the
|
2013-07-15 20:33:35 +02:00
|
|
|
host is configured to work with the board (Assuming that you are using
|
|
|
|
9600 baud for the data transfers -- high rates may result in data
|
|
|
|
overruns):
|
2013-07-14 20:34:45 +02:00
|
|
|
|
2013-07-16 19:23:35 +02:00
|
|
|
$ sudo stty -F /dev/ttyS0 9600 # Select 9600 (or other) BAUD
|
|
|
|
$ sudo stty -F /dev/ttyS0 crtscts # Enables CTS/RTS handshaking *
|
2013-07-15 20:33:35 +02:00
|
|
|
$ sudo stty -F /dev/ttyS0 # Show the TTY configuration
|
2013-07-14 20:34:45 +02:00
|
|
|
|
2013-07-16 19:23:35 +02:00
|
|
|
* Only is hardware flow control is enabled.
|
|
|
|
|
2013-07-15 20:33:35 +02:00
|
|
|
Start rz on the on the target. Here, in this example, we are using
|
|
|
|
/dev/ttyS1 to perform the transfer
|
2013-07-14 20:34:45 +02:00
|
|
|
|
|
|
|
nsh> rz -d /dev/ttyS1
|
|
|
|
|
2013-07-15 20:33:35 +02:00
|
|
|
/dev/ttyS1 or whatever device you select *MUST* support Hardware flow
|
|
|
|
control in order to throttle therates of data transfer to fit within the
|
|
|
|
allocated buffers.
|
|
|
|
|
2013-07-14 20:34:45 +02:00
|
|
|
Then use the sz command on Linux to send the file to the target:
|
|
|
|
|
|
|
|
$ sudo sz <filename> t </dev/ttyS0 >/dev/ttyS0
|
|
|
|
|
|
|
|
Where <filename> is the file that you want to send.
|
|
|
|
|
|
|
|
The resulting file will be found where you have configured the Zmodem
|
|
|
|
"sandbox" via CONFIG_SYSTEM_ZMODEM_MOUNTPOINT.
|
|
|
|
|
|
|
|
You can add the az -v option multiple times, each increases the level
|
|
|
|
of debug output. If you want to capture the Linux rz output, then
|
|
|
|
re-direct stderr to a log file by adding 2>az.log to the end of the
|
|
|
|
rz command.
|
|
|
|
|
|
|
|
If you don't have the az command on your Linux box, the package to
|
|
|
|
install rzsz (or possibily lrzsz).
|
2013-07-15 20:33:35 +02:00
|
|
|
|
2013-07-16 16:26:59 +02:00
|
|
|
Building the Zmodem Tools to Run Under Linux
|
|
|
|
============================================
|
|
|
|
|
2018-05-26 02:49:36 +02:00
|
|
|
Build support has been added so that the NuttX Zmodem implementation
|
|
|
|
can be executed on a Linux host PC. This can be done by
|
2013-07-16 16:26:59 +02:00
|
|
|
|
|
|
|
- Change to the apps/systems/zmodem directory
|
|
|
|
- Make using the special makefile, Makefile.host
|
|
|
|
|
|
|
|
NOTES:
|
|
|
|
|
|
|
|
1. TOPDIR and APPDIR must be defined on the make command line: TOPDIR is
|
|
|
|
the full path to the nuttx/ directory; APPDIR is the full path to the
|
|
|
|
apps/ directory. For example, if you installed nuttx at
|
|
|
|
/home/me/projects/nuttx and apps at /home/me/projects/apps, then the
|
|
|
|
correct make command line would be:
|
2013-07-16 00:21:20 +02:00
|
|
|
|
2013-07-16 16:26:59 +02:00
|
|
|
make -f Makefile.host TOPDIR=/home/me/projects/nuttx APPDIR=/home/me/projects/apps
|
|
|
|
|
2016-06-11 22:13:39 +02:00
|
|
|
2. Add CONFIG_DEBUG_FEATURES=1 to the make command line to enable debug output
|
2013-07-16 16:26:59 +02:00
|
|
|
3. Make sure to clean old target .o files before making new host .o files.
|
|
|
|
|
2013-07-16 19:23:35 +02:00
|
|
|
This build is has been verified as of 2013-7-16 using Linux to transfer
|
|
|
|
files with an Olimex LPC1766STK board. It works great and seems to solve
|
|
|
|
all of the problems found with the Linux sz/rz implementation.
|
2013-07-16 16:26:59 +02:00
|
|
|
|
|
|
|
Status
|
|
|
|
======
|
2013-07-16 19:23:35 +02:00
|
|
|
2013-7-15: Testing against the Linux rz/sz commands.
|
|
|
|
|
|
|
|
I have tested with the configs/olimex-lpc1766stk configuration. I
|
|
|
|
have been able to send large and small files with the target sz
|
|
|
|
command. I have been able to receive small files, but there are
|
|
|
|
problems receiving large files using the Linux sz command: The
|
|
|
|
Linux SZ does not obey the buffering limits and continues to send
|
|
|
|
data while rz is writing the previously received data to the file
|
|
|
|
and the serial driver's RX buffer is overrun by a few bytes while
|
|
|
|
the write is in progress. As a result, when it reads the next
|
|
|
|
buffer of data, a few bytes may be missing. The symptom of this
|
|
|
|
missing data is a CRC check failure.
|
2013-07-16 16:26:59 +02:00
|
|
|
|
|
|
|
Either (1) we need a more courteous host application, or (2) we
|
|
|
|
need to greatly improve the target side buffering capability!
|
|
|
|
|
|
|
|
My thought now is to implement the NuttX sz and rz commands as
|
|
|
|
PC side applications as well. Matching both sides and obeying
|
|
|
|
the handshaking will solve the issues. Another option might be
|
|
|
|
to fix the serial driver hardware flow control somehow.
|
|
|
|
|
2013-07-16 19:23:35 +02:00
|
|
|
2013-7-16. More Testing against the Linux rz/sz commands.
|
|
|
|
|
|
|
|
I have verified that with debug off and at lower serial BAUD
|
|
|
|
(2400), the transfers of large files succeed without errors. I do
|
2013-07-16 16:26:59 +02:00
|
|
|
not consider this a "solution" to the problem. I also found that
|
|
|
|
the LPC17xx hardware flow control caused strange hangs; Zmodem
|
|
|
|
works better with hardware flow control disabled on the LPC17xx.
|
2013-07-16 19:23:35 +02:00
|
|
|
|
|
|
|
At this lower BAUD, RX buffer sizes could probably be reduced; Or
|
|
|
|
perhaps the BAUD coud be increased. My thought, however, is that
|
|
|
|
tuning in such an unhealthy situation is not the approach: The
|
|
|
|
best thing to do would be to use the matching NuttX sz on the Linux
|
|
|
|
host side.
|
|
|
|
|
|
|
|
2013-7-16. More Testing against the NuttX rz/sz on Both Ends.
|
|
|
|
|
|
|
|
The NuttX sz/rz commands have been modified so that they can be
|
|
|
|
built and executed under Linux. In this case, there are no
|
|
|
|
transfer problems at all in either direction and with large or
|
|
|
|
small files. This configuration could probably run at much higher
|
|
|
|
serial speeds and with much smaller buffers (although that has not
|
|
|
|
been verified as of this writing).
|
|
|
|
|