Update README
This commit is contained in:
parent
73ec87109f
commit
ee46bf4d29
@ -72,6 +72,9 @@ On Board Debug Support
|
||||
Using the mikroProg
|
||||
===================
|
||||
|
||||
WARNING: This will most certainly overwrite the bootloader that was factory
|
||||
installed in FLASH!
|
||||
|
||||
Hardware setup
|
||||
--------------
|
||||
You will need to add a five pin header to the mikroProg connector between
|
||||
@ -194,6 +197,14 @@ Serial Console
|
||||
transceiver to get the signals to RS232 levels (or connect to the
|
||||
USB virtual COM port in the case of UART0).
|
||||
|
||||
STATUS: I have been unable to get the RS-232 Click to work in the mikroBUS
|
||||
A slot. The PIC32MZ does not receive serial input. It appears that there
|
||||
is an error in the some documentation: Either RG9 is not connect to
|
||||
UART4_RX or the PPS bit definitions are documented incorrectly for UART4.
|
||||
|
||||
Switching to UART3 eliminates the problem and the serial console is fully
|
||||
functional.
|
||||
|
||||
SPI
|
||||
===
|
||||
|
||||
@ -339,9 +350,9 @@ Where <subdir> is one of the following:
|
||||
|
||||
NOTES:
|
||||
|
||||
1. Serial Console. UART 4 is configured as the Serial Console. This
|
||||
1. Serial Console. UART3 is configured as the Serial Console. This
|
||||
assumes that you will be using a Mikroe RS-232 Click card in the
|
||||
mikroBUS A slot. Other serial consoles may be selected by re-
|
||||
mikroBUS B slot. Other serial consoles may be selected by re-
|
||||
configuring (see the section "Serial Consoles" above).
|
||||
|
||||
2. Toolchain
|
||||
|